Altivar® 58 TRX AC Drives

Parameter Summary

PARAMETER SUMMARY

The following tables show the ATV58 TRX Type H configuration parameters. This page can be copied and used as a worksheet to customize settings for your application.

Adjustment Parameters

Code

Fact. Setting

Cust. Setting

Code

Fact. Setting

Cust. Setting

 

 

 

 

 

 

ACb

no

 

SP6

30 Hz

Hz

 

 

 

 

 

 

ACC

3 s

s

SP7

35 Hz

Hz

 

 

 

 

 

 

dEc

3 s

s

JOG

10 Hz

Hz

 

 

 

 

 

 

LSP

0 Hz

Hz

JGt

0.5 s

s

 

 

 

 

 

 

HSP

50 / 60 Hz

Hz

brL

0 Hz

Hz

 

 

 

 

 

 

FLG

20%

%

Ibr

0 A

A

 

 

 

 

 

 

StA

20%

%

brt

0 s

s

 

 

 

 

 

 

ItH

0.9 of In

A

bEn

0 Hz

Hz

IdC

0.7 ItH

A

bEt

0 s

s

 

 

 

 

 

 

tdC

0.5 s

s

FFt

50/60 Hz

Hz

 

 

 

 

 

 

SdC

Varies

A

rPG

1

 

 

 

 

 

 

 

JPF

0 Hz

Hz

rIG

1 / s

/ s

 

 

 

 

 

 

JF2

0 Hz

Hz

PSP

0.0 s

s

 

 

 

 

 

 

JF3

0 Hz

Hz

FbS

0.1

 

 

 

 

 

 

 

AC2

5 s

s

PIC

no

 

 

 

 

 

 

 

dE2

5 s

s

PI2

30%

%

 

 

 

 

 

 

tLS

no

no or s

PI3

60%

%

 

 

 

 

 

 

USC

1

 

dtd

105%

%

 

 

 

 

 

 

UFr

100%

%

dtS

1

 

 

 

 

 

 

 

SLP

100%

%

Ctd

1.36 of In

A

PFL

20%

%

ttd

100%

%

 

 

 

 

 

 

SP2

10 Hz

Hz

tL2

200%

%

 

 

 

 

 

 

SP3

15 Hz

Hz

Ftd

50/60 Hz

Hz

 

 

 

 

 

 

SP4

20 Hz

Hz

F2d

50/60 Hz

Hz

 

 

 

 

 

 

SP5

25 Hz

Hz

 

 

 

 

 

 

 

 

 

Drive Menu Parameters

Code

Factory Setting

Customer Setting

Code

Factory Setting

Customer Setting

 

 

 

 

 

 

UnS

depends on catalog number

V

Stt

STN

 

 

 

 

 

 

 

FrS

50 / 60 Hz

Hz

dCF

4

 

 

 

 

 

 

 

nCr

0.9 of In

A

tLI

200%

%

 

 

 

 

 

 

nSP

depends on catalog number

rpm

CLI

1.3 6 of In

 

 

 

 

 

 

 

COS

depends on catalog number

 

AdC

yes

 

 

 

 

 

 

 

tUn

no

 

PCC

1

 

 

 

 

 

 

 

tFr

60 / 72 Hz

Hz

SFt

LF

 

 

 

 

 

 

 

nLd

no

 

SFr

depends on catalog number

kHz

 

 

 

 

 

 

Fdb

no

 

nrd

yes

 

 

 

 

 

 

 

Frt

0 Hz

Hz

SPC

no

 

 

 

 

 

 

 

rPt

LIN

 

PGt

DET

 

 

 

 

 

 

 

brA

no

 

PLS

1024

 

 

 

 

 

 

 

Command Menu Parameters

 

 

 

 

 

Code

Factory Setting

Customer Setting

Code

Factory Setting

Customer Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tCC

2 W

 

 

 

AOH

20 mA

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

tCt

LEL

 

 

 

Str

no

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rln

no

 

 

 

LCC

no

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bSP

no

 

 

 

PSt

yes

 

 

 

 

 

 

 

 

 

 

 

 

 

CrL

4 mA

mA

Add

0

 

 

 

 

 

 

 

 

 

 

 

 

 

CrH

20 mA

mA

tbr

19200

 

 

 

 

 

 

 

 

 

 

 

 

 

AOL

0 mA

mA

rPr

no

 

 

74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 2000–2003 Schneider Electric All Rights Reserved

 

 

 

 

 

09/2003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 74
Image 74
Schneider Electric 58 TRX manual Parameter Summary, Adjustment Parameters, Drive Menu Parameters, Command Menu Parameters