Line Reactors–208/230 V Rated Three Phase
208 V Drive Rating 230 V Drive Rating Open Style
Part Number
Enclosed
Part Number
(NEMA Type 1)
Approx.
Wt.
(lbs.)
Enclosure
Dimensions
HxWxD
(in.)
HP kW HP kW
1 . . . 1 . . . RL00402 RL00412 11 8x8x6
1.5–2 . . . 1.5–2 . . . RL00802 RL00812 15 8x8x6
3 . . . 3 . . . RL01202 RL01212 17 8x8x6
5 . . . 5 . . . RL01802 RL01812 19 8x8x6
7.5 . . . 7.5 . . . RL02502 RL02512 45 15x13x13
10 . . . 10 . . . RL03502 RL03512 47 15x13x13
15 . . . 15 . . . RL04502 RL04512 59 15x13x13
20 . . . 20 . . . RL05502 RL05512 59 15x13x13
25 . . . 25–30 . . . RL08002 RL08012 82 15x13x13
30 . . . 40 . . . RL10002 RL10012 82 15x13x13
40 . . . 50 . . . RL13002 RL13012 88 15x13x13
50 . . . . . . . . . RL16002 RL16012 88 15x13x13
Line Reactors–208/230 V Rated Single Phase
208 V Drive Rating 230 V Drive Rating Open Style
Part Number
Enclosed
Part Number
(NEMA Type 1)
Approx.
Wt.
(lbs.)
Enclosure
Dimensions
HxWxD
(in.)
HP kW HP kW
.5 . . . .5–1 . . . RL00802 RL00812 15 8x8x6
1 . . . 2 . . . RL01202 RL01212 17 8x8x6
2 . . . 3 . . . RL01802 RL01812 19 8x8x6
3 . . . . . . . . . RL02502 RL02512 45 15x13x13
. . . 3 . . . 3 RL03502 RL03512 47 15x13x13
5 . . . 5 . . . RL04502 RL04512 59 15x13x13
7.5 . . . 7.5 . . . RL08002 RL08012 82 15x13x13
480 V Rated Type 1 Enclosed Motor Protection Output Filters (UL508A)
HP
AKLCUL Filter Enclosed
Part Number
Approx.
Wt.
(lbs.)
Enclosure Dimensions
Drive 460 V
Rating
HW D
in. mm in. mm in. mm
1–2 4 KLCUL4A1 15 12.25 311 12.50 318 6.75 171
3 6 KLCUL6A1 15 12.25 311 12.50 318 6.75 171
5 8 KLCUL8A1 15 12.25 311 12.50 318 6.75 171
7.5 12 KLCUL12A1 15 12.25 311 12.50 318 6.75 171
10 16 KLCUL16A1 17 12.25 311 12.50 318 6.75 171
15 25 KLCUL25A1 20 12.25 311 12.50 318 6.75 171
20–25 35 KLCUL35A1 20 12.25 311 12.50 318 6.75 171
30 45 KLCUL45A1 20 12.25 311 12.50 318 6.75 171
40 55 KLCUL55A1 20 12.25 311 12.50 318 6.75 171
50–60 80 KLCUL80A2 56 19.13 486 15.50 394 15.50 394
75 110 KLCUL110A2 60 19.13 486 15.50 394 15.50 394
100 130 KLCUL130A2 66 19.13 486 15.50 394 15.50 394
125 160 KLCUL160A2 80 19.13 486 15.50 394 15.50 394
150 200 KLCUL200A3 102 22.13 562 20.50 521 24.37 619
200 250 KLCUL250A3 110 22.13 562 20.50 521 24.37 619
250 300 KLCUL300A3 115 22.13 562 20.50 521 24.37 619
300 360 KLCUL360A3 125 22.13 562 20.50 521 24.37 619
350 420 KLCUL420A3 145 22.13 562 20.50 521 24.37 619
400 480 KLCUL480A3 150 22.13 562 20.50 521 24.37 619
450–500 600 KLCUL600A3 167 22.13 562 20.50 521 24.37 619
Output Filters
NOTE: Line reactors and filters are intended for separate mounting and wiring by the user. Ratings are based on NEC (NFPA 70) 430-150 current ratings. If the drive has a higher FLA rating, use the “A” rating to select the appropriate filter.
Output Filters.tif