ATV58NEMAb_w no back.tif
ATV58 TRX Type F Product Family
09/2003
Altivar® 58 TRX AC Drives
Type F Drive Controllers
ATV58 TRX TYPE F DRIVE CONTROLLERS
The ATV58 TRX family of
•1 to 7.5 hp (0.75 to 5.5 kW), 400/460 Vac,
•½ to 3 hp (0.37 to 2.2 kW), 200/240 Vac,
•2 to 3 hp (1.5 to 2.2 kW), 200/240 Vac,
Each ATV58 TRX Type F drive controller contains:
•A Vario load break switch, input line fuses, and an ATV58 TRX drive controller
•Start Stop push buttons
•A manual speed potentiometer mounted on the front of the enclosure
•Space for one additional
•Four conduit openings that are closed with plugs
•A transparent plastic door to allow viewing of status LEDs and a separately supplied keypad
All ATV58 TRX communications and I/O options can be used in the Type F drive controllers. The Type F drive controllers can be used on constant or variable torque applications. The ratings are shown in the tables below.
200 Vac
Frame | Drive Controller | Motor Power▼ | Rated | Transient | ||
Output Current | Output Current◆ | |||||
Size▲ | Catalog Number |
|
|
|
|
|
kW |
| HP | A | A | ||
|
|
| ||||
|
|
|
|
|
|
|
1 | ATV58EU09M2FZU |
| 0.37 | 0.5 | 2.3 | 3.1 |
|
|
|
|
|
|
|
1 | ATV58EU18M2FZU |
| 0.75 | 1 | 4.1 | 5.6 |
|
|
|
|
|
|
|
2 | ATV58EU29M2FZU |
| 1.5 | 2 | 7.8 | 10.6 |
|
|
|
|
|
|
|
3 | ATV58EU41M2FZU■ |
| 2.2 | 3 | 11 | 15 |
200 Vac | ||||||
|
|
|
|
|
|
|
Frame | Drive Controller | Motor Power▼ | Rated | Transient | ||
Output Current | Output Current◆ | |||||
Size▲ | Catalog Number |
|
|
|
|
|
kW |
| HP | A | A | ||
|
|
| ||||
|
|
|
|
|
|
|
2 | ATV58EU29M2FZU |
| 1.5 | 2 | 7.8 | 10.6 |
|
|
|
|
|
|
|
3 | ATV58EU41M2FZU |
| 2.2 | 3 | 11 | 15 |
|
|
|
|
|
| |
400 Vac | ||||||
|
|
|
|
|
|
|
Frame | Drive Controller | Motor Power▼ | Rated | Transient | ||
Output Current | Output Current◆ | |||||
Size▲ | Catalog Number |
|
|
|
|
|
kW |
| HP | A | A | ||
|
|
| ||||
|
|
|
|
|
|
|
2 | ATV58EU18N4FZU |
| 0.75 | 1 | 2.3 | 3.1 |
|
|
|
|
|
|
|
2 | ATV58EU29N4FZU |
| 1.5 | 2 | 4.1 | 5.6 |
|
|
|
|
|
|
|
2 | ATV58EU41N4FZU |
| 2.2 | 3 | 5.8 | 7.9 |
|
|
|
|
|
|
|
3 | ATV58EU54N4FZU |
| 3 | – | 7.8 | 10.6 |
|
|
|
|
|
|
|
3 | ATV58EU72N4FZU |
| 4 | 5 | 10.5 | 14.3 |
|
|
|
|
|
|
|
3 | ATV58EU90N4FZU |
| 5.5 | 7.5 | 13 | 17.7 |
|
|
|
|
|
|
|
▲For dimensions, see page 122; for wiring diagrams, see pages 111 and 112.
▼Power indicated is for a switching frequency between 0.5 and 4 kHz, and at steady state. For switching frequency between 8 and 16 kHz, use the next largest size drive controller. (For example, for 2 hp, order drive controller ATV58EU41M2FZU.) If the duty cycle (that is, the drive controller run time) does not exceed 60% (36
second maximum for a 60 second cycle), this is not necessary.
◆For 60 seconds.
■A line reactor (3% minimum) must be used with this drive controller.
13
©