ATV58NEMAb_w no back.tif

ATV58 TRX Type F Product Family

09/2003

Altivar® 58 TRX AC Drives

Type F Drive Controllers

ATV58 TRX TYPE F DRIVE CONTROLLERS

The ATV58 TRX family of adjustable-frequency AC drive controllers is used to control three-phase asynchronous motors. ATV58 TRX Type F models contain an ATV58 TRX Type H drive controller packaged in a compact Type 12 enclosure. They are for use in mechanical rooms, OEM equipment, and factory floor applications requiring a local load break switch and input line fusing. The following models are available:

1 to 7.5 hp (0.75 to 5.5 kW), 400/460 Vac, three-phase input

½ to 3 hp (0.37 to 2.2 kW), 200/240 Vac, single-phase input

2 to 3 hp (1.5 to 2.2 kW), 200/240 Vac, three-phase input

Each ATV58 TRX Type F drive controller contains:

A Vario load break switch, input line fuses, and an ATV58 TRX drive controller

Start Stop push buttons

A manual speed potentiometer mounted on the front of the enclosure

Space for one additional 16-mm operator

Four conduit openings that are closed with plugs

A transparent plastic door to allow viewing of status LEDs and a separately supplied keypad

All ATV58 TRX communications and I/O options can be used in the Type F drive controllers. The Type F drive controllers can be used on constant or variable torque applications. The ratings are shown in the tables below.

200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, Single-Phase Input with 3-Phase Output

Frame

Drive Controller

Motor Power

Rated

Transient

Output Current

Output Current

Size

Catalog Number

 

 

 

 

 

kW

 

HP

A

A

 

 

 

 

 

 

 

 

 

 

1

ATV58EU09M2FZU

 

0.37

0.5

2.3

3.1

 

 

 

 

 

 

 

1

ATV58EU18M2FZU

 

0.75

1

4.1

5.6

 

 

 

 

 

 

 

2

ATV58EU29M2FZU

 

1.5

2

7.8

10.6

 

 

 

 

 

 

 

3

ATV58EU41M2FZU

 

2.2

3

11

15

200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output

 

 

 

 

 

 

 

Frame

Drive Controller

Motor Power

Rated

Transient

Output Current

Output Current

Size

Catalog Number

 

 

 

 

 

kW

 

HP

A

A

 

 

 

 

 

 

 

 

 

 

2

ATV58EU29M2FZU

 

1.5

2

7.8

10.6

 

 

 

 

 

 

 

3

ATV58EU41M2FZU

 

2.2

3

11

15

 

 

 

 

 

 

400 Vac -10% / 460 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output

 

 

 

 

 

 

 

Frame

Drive Controller

Motor Power

Rated

Transient

Output Current

Output Current

Size

Catalog Number

 

 

 

 

 

kW

 

HP

A

A

 

 

 

 

 

 

 

 

 

 

2

ATV58EU18N4FZU

 

0.75

1

2.3

3.1

 

 

 

 

 

 

 

2

ATV58EU29N4FZU

 

1.5

2

4.1

5.6

 

 

 

 

 

 

 

2

ATV58EU41N4FZU

 

2.2

3

5.8

7.9

 

 

 

 

 

 

 

3

ATV58EU54N4FZU

 

3

7.8

10.6

 

 

 

 

 

 

 

3

ATV58EU72N4FZU

 

4

5

10.5

14.3

 

 

 

 

 

 

 

3

ATV58EU90N4FZU

 

5.5

7.5

13

17.7

 

 

 

 

 

 

 

For dimensions, see page 122; for wiring diagrams, see pages 111 and 112.

Power indicated is for a switching frequency between 0.5 and 4 kHz, and at steady state. For switching frequency between 8 and 16 kHz, use the next largest size drive controller. (For example, for 2 hp, order drive controller ATV58EU41M2FZU.) If the duty cycle (that is, the drive controller run time) does not exceed 60% (36

second maximum for a 60 second cycle), this is not necessary.

For 60 seconds.

A line reactor (3% minimum) must be used with this drive controller.

13

© 2000–2003 Schneider Electric All Rights Reserved

Page 13
Image 13
Schneider Electric manual ATV58 TRX Type F Drive Controllers, ATV58 TRX Type F Product Family