Altivar® 58 TRX AC Drives

Selection

External RFI Input Filters

 

 

Maximum Length of

 

 

 

 

 

Shielded Cable[1]

Nominal

 

 

 

 

EN 55011

EN 55022

Current (In)

 

Catalog

Supply Voltage

ATV58 Models

Class A

Class B

of the Filter

Weight

Number

 

 

 

 

 

 

 

Single-Phase

ATV58•U09M2, ATV58•U18M2

50 m/164 ft

20 m/65 ft

10 A

1.7 kg/3.7 lb

VW3A58401

200 to 240 Vac

 

 

 

 

 

 

ATV58•U29M2, ATV58•U41M2

50 m/164 ft

20 m/65 ft

25 A

3.6 kg/7.9 lb

VW3A58402

50/60 Hz

 

 

 

 

 

 

 

ATV58•U72M2

50 m/164 ft

20 m/65 ft

25 A

5.0 kg/11.0 lb

VW3A58403

 

 

 

 

 

 

 

 

ATV58•U90M2, ATV58•D12M2

50 m/164 ft

20 m/65 ft

40 A

10.0 kg/22.0 lb

VW3A58404

 

 

 

 

 

 

 

3-Phase

ATV58•U29M2, ATV58•U41M2

50 m/164 ft

20 m/65 ft

25 A

3.6 kg/7.9 lb

VW3A58402

200 to 240 Vac

 

 

 

 

 

 

ATV58•U54M2, ATV58•U72M2

50 m/164 ft

20 m/65 ft

25 A

5.0 kg/11.0 lb

VW3A58403

50/60 Hz

 

 

 

 

 

 

 

ATV58•U90M2, ATV58•D12M2

50 m/164 ft

20 m/65 ft

45 A

10.0 kg/22.0 lb

VW3A58404

 

 

 

 

 

 

 

3-Phase

ATV58HD16M2X, ATV58HD23M2X

n/a

n/a

80 A

13.0 kg/28.6 lb

VW3A58407

208 to 240 Vac

 

 

 

 

 

 

ATV58HD28M2X, ATV58HD33M2X,

n/a

n/a

160 A

20.0 kg/44.0 lb

VW3A58408

50/60 Hz

ATV58HD46M2X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-Phase

ATV58•U18N4, ATV58•U29N4,

50 m/164 ft

20 m/65 ft

25 A

3.6 kg/7.9 lb

VW3A58402

400 to 460 Vac

ATV58•U41N4

 

 

 

 

 

50/60 Hz

 

 

 

 

 

 

ATV58•U54N4, ATV58•U72N4,

50 m/164 ft

20 m/65 ft

25 A

5.0 kg/11.0 lb

VW3A58403

 

 

ATV58•U90N4

 

 

 

 

 

 

 

 

 

 

 

 

 

ATV58•D12N4, ATV58•D16N4

50 m/164 ft

20 m/65 ft

45 A

10.0 kg/22.0 lb

VW3A58404

 

 

 

 

 

 

 

 

ATV58•D23N4

50 m/164 ft

20 m/65 ft

45 A

13.0 kg/28.6 lb

VW3A58405

 

 

 

 

 

 

 

 

ATV58HD28N4

200 m/656 ft

100 m/328 ft

50 A

13.0 kg/28.6 lb

VW3A58406

 

 

 

 

 

 

 

 

ATV58HD33N4, ATV58HD46N4

200 m/656 ft

100 m/328 ft

80 A

13.0 kg/28.6 lb

VW3A58407

 

 

 

 

 

 

 

 

ATV58HD54N4, ATV58HD64N4,

200 m/656 ft

100 m/328 ft

160 A

20.0 kg/44.0 lb

VW3A58408

 

ATV58HD79N4

 

 

 

 

 

 

 

 

 

 

 

 

[1]The filter selection tables give the maximum length for the shielded cables which connect the motors to the drive controllers for a switching frequency of 0.5 to 12 kHz. These limits are given for information only as they depend on the interference capacity of the motors and the cables used. For motors connected in parallel, the total of the lengths must be taken into account.

Line Reactors.tif

Line Reactors

Line Reactors—480 V Rated Three Phase

460 V Drive Rating

 

 

Approx.

Enclosure

 

 

Open Style

Enclosed

Dimensions

 

 

Wt.

HP

kW

Part Number

Part Number

HxWxD

(lbs.)

 

 

 

 

(in.)

 

 

 

 

 

 

 

 

 

 

 

1

. . .

RL00202

RL00212

11

8x8x6

2–3

. . .

RL00403

RL00413

12

8x8x6

5

. . .

RL00803

RL00813

18

15x13x13

7.5

. . .

RL01203

RL01213

25

15x13x13

10

. . .

RL01803

RL01813

49

15x13x13

 

 

 

 

 

 

15

. . .

RL02503

RL02513

49

15x13x13

20–25

. . .

RL03503

RL03513

61

15x13x13

30

. . .

RL04503

RL04513

70

15x13x13

40

. . .

RL05503

RL05513

72

15x13x13

50–60

. . .

RL08003

RL08013

86

15x13x13

 

 

 

 

 

 

75

. . .

RL10003

RL10013

105

15x13x13

100

. . .

RL13003

RL13013

105

15x13x13

125

. . .

RL16003

RL16013

105

15x13x13

150

. . .

RL20003

RL20013

131

15x13x13

200

. . .

RL25003

RL25013

185

24x17x17

 

 

 

 

 

 

250

. . .

RL32003

RL32013

235

24x17x17

300

. . .

RL40003

RL40013

245

24x17x17

350–400

. . .

RL50003

RL50013

335

24x17x17

450–500

. . .

RL60003

RL60013

335

24x17x17

 

 

 

 

 

 

NOTE: Line reactors and filters are intended for separate mounting and wiring by the user. Ratings are based on NEC (NFPA 70) 430-150 current ratings. If the drive has a higher FLA rating, use the “A” rating to select the appropriate filter.

132

© 2000–2003 Schneider Electric All Rights Reserved

 

09/2003

 

 

 

 

Page 132
Image 132
Schneider Electric 58 TRX manual External RFI Input Filters, Line Reactors-480 V Rated Three Phase, 132