Altivar® 58 TRX AC Drives
Type H Drive Controllers
© 2000–2003 Schneider Electric All Rights Reserved
809/2003
Ratings
ATV5 8 TRX Type H drive controllers may be rated for constant torque (CT), variable torque (VT), and
variable torque low noise (VTLN) applications.
CT applications usually require 100% of motor-rated torque through the entire speed range, high
transient torque capability, and speed regulation.
VT applications, such as centrifugal fans and centrifugal pumps, do no t require hig h transie nt torque
capability. This typically allows a drive to be rate d for ad ditional hors epower an d additional current as
compared to the constant torque rating.
VTLN applications, such as centrifugal fans and centrifugal pumps, do not require high transient
torque capability. However, this rating uses a higher switching frequency for quiet er motor oper ation.
As a result, the drive may be rated at the same horsepower and current as the consta nt torque rating,
particularly at large horsepower sizes.
The 125–500 hp drive controllers are listed in this catalog with r atings typi cally use d for VT application s.
With proper selection, this range of controllers can also be used in CT applications, such as
compressors, conveyors, and extruders, where high performance is not required at low speeds. The
125–500 hp product ratings in this catalog are for applications that require 100% rated torque down to
6 Hz. If the application requires more than 110% transient torque for one minute , select th e appropriate
horsepower product. For assistance with selecting the proper AC drive controller for constant torque
applications, consult your local Square D drives specialist.
Application information is also available in product data bulletin SC100, Adjustable Frequency
Controllers Application Guide, available at www.SquareD.com, or the NEMA Standards Publication:
Application Guide For AC Adjustable Speed Drive Systems.
Ratings for ATV58 TRX Type H Constant Torque; 208/230 Vac, Single-Phase Input with 3-Phase Output;
Switching Frequency at 4 kHz
Frame Size Drive Controller
Catalog Number
Motor Power
208/230 Vac Rated
Output Current Transient
Output Current Total Dissipated
Power at Rated Load
kW HP A A W
1 ATV58HU09M2ZU 0.37 0.5 2.3 3.1 42
1 ATV58HU18M2ZU 0.75 1 4.1 5.6 64
2 ATV58HU29M2ZU 1.5 2 7.8 10.6 107
2 ATV58HU41M2ZU 2.2 3 11 15.0 156
3 ATV58HU72M2ZU3 4 13.7 18.6 160
4 ATV58HU90M2ZU4 5 18.2 24.8 176
4 ATV58HD12M2ZU5.5 7.5 24.2 32.9 204
Ratings for ATV58 TRX Type H Variable Torque, Low Noise; 208/230 Vac, Single-Phase Input with 3-Phase Output;
Switching Frequency: ATV58HU09M2–D12M2 at 8 kHz; ATV58HD16M2–D46M2 at 4 KHz
Frame Size Drive Controller
Catalog Number
Motor Power
208/230 Vac Rated
Output Current Transient
Output Current Total Dissipated
Power at Rated Load
kWHPAAW
1 ATV58HU09M2ZU 0.37 0.5 2.5 2.8 42
1 ATV58HU18M2ZU 0.75 1 4.8 5.3 64
2 ATV58HU29M2ZU 1.5 2 7.8 8.6 107
2 ATV58HU41M2ZU 2.2 3 11 12.1 156
3 ATV58HU72M2ZU3 4 14.3 15.7 160
4 ATV58HU90M2ZU4 5 17.5 19.3 176
4 ATV58HD12M2ZU5.5 7.5 25.3 27.8 204
6 ATV58HD16M2XZU7.5 10 30.8 33.9 323
6 ATV58HD23M2XZU11 15 46.2 50.8 550
7 ATV58HD28M2XZU15 20 60 66.0 745
7 ATV58HD33M2XZU18.5 25 75 82.5 895
7 ATV58HD46M2XZU22 30 88 96.8 900
Refer to page 127 for a
complete list of catalog
numbers. An “X” in the
catalog number indicates that
the product does not have an
internal EMC filter. If an
internal EMC filter is required,
delete the “X” from the
catalog number.
When these drive controllers
are used with a single-phase
input, a line reactor (3%
minimum) must be used.
Refer to page 127 for a
complete list of catalog
numbers. An “X” in the
catalog number indicates that
the product does not have an
internal EMC filter. If an
internal EMC filter is required,
delete the “X” from the
catalog number.
When these drive controllers
are used with a single-phase
input, a line reactor (3%
minimum) must be used.