Altivar® 58 TRX AC Drives

Configurable I/O Functions

Analog Input 1 (AI1) is configured for 0 to 10 Vdc speed reference input. It is factory-configured to sum with other analog inputs. AI1 is designated as Speed Reference 1 when Reference Switching (Hand Auto mode) is configured. AI1 is designated as Set Point Reference when the PI regulator function is configured.

Possible Assignments

Assignable I/O

Assignable I/O with Optional I/O Extension Card

on the ATV58 TRX Controller

Analog I/O Extension Card

Digital I/O Extension Card

 

 

 

LI2

 

 

LI5

 

 

 

LI5

 

 

A+ A–

Function

AI2

LI3

R2

AO

LO

AO

AI3

LO

AO

LI6

LI6

B+ B–

 

 

LI4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reverse Operation

 

 

 

 

 

 

 

 

 

 

 

 

Ramp Switching

 

 

 

 

 

 

 

 

 

 

 

 

Jog Operation

 

 

 

 

 

 

 

 

 

 

 

 

+/– Speed

 

 

 

 

 

 

 

 

 

 

 

 

Setpoint Memory

 

 

 

 

 

 

 

 

 

 

 

 

Preset Speeds

 

 

 

 

 

 

 

 

 

 

 

 

Freewheel Stop

 

 

 

 

 

 

 

 

 

 

 

 

Fast Stop

 

 

 

 

 

 

 

 

 

 

 

 

DC Injection Braking

 

 

 

 

 

 

 

 

 

 

 

 

Motor Switching

 

 

 

 

 

 

 

 

 

 

 

 

Second Torque Limit

 

 

 

 

 

 

 

 

 

 

 

 

Forced Local

 

 

 

 

 

 

 

 

 

 

 

 

Fault Reset

 

 

 

 

 

 

 

 

 

 

 

 

Reference Switching

 

 

 

 

 

 

 

 

 

 

 

 

Auto Tune

 

 

 

 

 

 

 

 

 

 

 

 

PI Auto/Manual

 

 

 

 

 

 

 

 

 

 

 

 

PI Preset Setpoints

 

 

 

 

 

 

 

 

 

 

 

 

External Faults

 

 

 

 

 

 

 

 

 

 

 

 

Torque Limit Switching

 

 

 

 

 

 

 

 

 

 

 

 

Summing Reference

 

 

 

 

 

 

 

 

 

 

 

 

PI Regulator Feedback

 

 

 

 

 

 

 

 

 

 

 

 

PI Manual Speed Reference

 

 

 

 

 

 

 

 

 

 

 

 

Second Speed Reference

 

 

 

 

 

 

 

 

 

 

 

 

Speed Feedback

 

 

 

 

 

 

 

 

 

 

 

 

PTC Motor Probes

 

 

 

 

 

 

 

 

 

 

 

 

Torque Limit (Analog)

 

 

 

 

 

 

 

 

 

 

 

 

Drive Running

 

 

 

 

 

 

 

 

 

 

 

 

Output Contactor Control

 

 

 

 

 

 

 

 

 

 

 

 

Reference Speed Attained

 

 

 

 

 

 

 

 

 

 

 

 

High Speed Attained

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Level Attained

 

 

 

 

 

 

 

 

 

 

 

 

Current Level Attained

 

 

 

 

 

 

 

 

 

 

 

 

Motor Thermal Level Attained

 

 

 

 

 

 

 

 

 

 

 

 

Drive Thermal Level Attained

 

 

 

 

 

 

 

 

 

 

 

 

Loss of Follower (4–20 mA)

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Level 2 Attained

 

 

 

 

 

 

 

 

 

 

 

 

Brake Sequence

 

 

 

 

 

 

 

 

 

 

 

 

Motor Current

 

 

 

 

 

 

 

 

 

 

 

 

Motor Frequency

 

 

 

 

 

 

 

 

 

 

 

 

Ramp Output

 

 

 

 

 

 

 

 

 

 

 

 

Motor Torque

 

 

 

 

 

 

 

 

 

 

 

 

Signed Motor Torque

 

 

 

 

 

 

 

 

 

 

 

 

Signed Ramp

 

 

 

 

 

 

 

 

 

 

 

 

PI Reference

 

 

 

 

 

 

 

 

 

 

 

 

PI Feedback

 

 

 

 

 

 

 

 

 

 

 

 

PI Error

 

 

 

 

 

 

 

 

 

 

 

 

PI Integral

 

 

 

 

 

 

 

 

 

 

 

 

Motor Power

 

 

 

 

 

 

 

 

 

 

 

 

Motor Thermal

 

 

 

 

 

 

 

 

 

 

 

 

Drive Thermal

 

 

 

 

 

 

 

 

 

 

 

 

51

09/2003

 

© 2000–2003 Schneider Electric All Rights Reserved

 

 

 

 

Page 51
Image 51