Enclosure Types

The Class 8839 58M Enclosed AC drives are available in Type 1, Type 1G, or Type 12 enclosures. If Type 3R, 4, or 4X enclosures are required, consult product support or customer service for enclosed drives.

Outside installations requiring drives should be quoted for installation in climate controlled Type 3R walk-in enclosures available separately from our Power Zone Center group in Smyrna, TN.

Specifications for Drive Controllers

Class 8839 58M Enclosed AC Drives

Application Information

Relay Contact Ratings

Interposing relay contacts are available for customer use. Contacts are available for run and fault indication as standard. Optional contacts (if selected) provide indication of bypass on, auto mode, and communication mode. Relay contacts are rated for switching inductive loads and have a 5 A continuous current rating.

Input voltage

460 V ±10%, 230 V ±10%, 208 V±10%

 

 

Displacement power factor

98% through speed range

 

 

Input frequency

60 Hz ± 5%

 

 

Output voltage

Three-phase output

Maximum voltage equal to input voltage

 

 

 

Galvanic isolation

Galvanic isolation between power and control

(inputs, outputs, and power supplies)

 

 

 

Frequency range of power converter

0.1 to 500 Hz (factory setting of 60 Hz)

 

 

Torque/overtorque

110% of nominal motor torque for 60 s (VT)

150% of nominal motor torque for 60 s (CT)

 

 

 

Current

110% of controller rated current for 60 s

 

 

 

Selectable from 0.5 to 16 kHz [1]

 

Factory setting:

Switching frequency

4 kHz CT,

 

8 kHz for 208 V, 230 V, and 1–100 hp @460 V VT

 

2 kHz for 125–500 hp @ 460 V VT

 

 

 

AI1: 0 to +10 V, Impedance = 30 k

 

Speed potentiometer to AI1

Speed reference

AI2: factory setting: 4 to 20 mA,

Impedance = 100 (reassignable, X–Y range with keypad display).

 

 

Factory modification J10 provides a controller interface 0–10 Vdc reference signal

 

to the AI2 input using a 0–10 V / 4–20 mA converter with Z= 40 k.

 

 

Frequency resolution in analog reference

0.1 for 100 Hz (10 bits)

 

 

Speed regulation

V/f: determined by motor slip, typically 3%

Sensorless flux vector (SLFV): 1%

 

 

 

Efficiency

97% at full load typical

 

 

Reference sample time

5 ms

 

 

Acceleration and deceleration ramps

0.1 to 999.9 s (definition in 0.1 s increments)

 

 

 

Thermal protection of transformer, rectifier, and power converter

Drive controller protection

Phase loss of AC mains

 

Circuit breaker rated at 65 kAIC

 

 

Motor protection

Class 10 electronic overload protection

Class 20 electromechanical overload protection with bypass [2]

 

Keypad display

Self diagnostics with fault messages in three languages; also refer to instruction

bulletin VVDED397047US

 

 

 

Temperature

Storage for all enclosures: -13 to +149 °F (-25 to +65 °C)

Operation: +14 to +104 °F (-10 to 40 °C)

 

 

 

Humidity

95% with no condensation or dripping water, conforming to IEC 60068-2-3.

 

 

Altitude

3,300 ft (1000 m) maximum without derating; derating of the current by 1% for each

additional 330 ft (100 m)

 

 

 

 

Type 1: all controllers

Enclosure

Type 1G: 125–500 hp @ 460 V VT only

 

Type 12: all except 125–500 hp @ 460 V VT

 

 

1.1–100 hp switching frequency is factory set below 4 kHz. If operation above 4 kHz (CT) or 8 kHz (VT) is required, select the next largest size drive controller. 125–500 hp switching frequency is factory set at 2 kHz. If operation above 2 kHz is required, select the next largest size drive controller.

2.Class 10 electromechanical for 1 hp @ 460 V.

09/2003

173

© 2000–2003 Schneider Electric All Rights Reserved

Page 173
Image 173