Class 8839 58M Enclosed AC Drives
Drive Selection
The following tables define the available factory modifications for the Class 8839 58M Enclosed AC Drives. These factory modifications offer maximum flexibility for many complex job specifications. All modifications follow specific interoperability rules for selection. Modification selection can be validated at time of quotation or order entry by the Square D Quote to Cash Product Selector.
| ❼ Control Options | |
Code | AFC Controls | |
A07 | Hand/Off/Auto, Speed Potentiometer | |
B07 | Hand/Off/Auto, Start/Stop, Speed Potentiometer | |
C07 | Start/Stop, Speed Potentiometer | |
D07 | Stop/Start, Forward/Reverse, Speed Potentiometer | |
E07 | Hand/Off/Auto, Local/Remote, Speed Potentiometer | |
F07 | Communication/Auto/Off/Hand, Speed Potentiometer | |
|
| |
| ❽ Light Options | |
Code | Light cluster | |
| Red Power On | |
|
| |
A08 | Green AFC Run | |
| ||
Yellow AFC Fault | ||
| ||
|
| |
| Yellow Auto | |
| Red Power On | |
|
| |
B08 | Green AFC Run | |
| ||
Yellow AFC Fault | ||
| ||
|
| |
| Yellow Bypass | |
| Red Power On | |
C08 |
| |
Green AFC Run | ||
|
| |
| Yellow AFC Fault | |
| Red Power On | |
|
| |
D08 | Yellow AFC Fault | |
| ||
Green Run Forward | ||
| ||
|
| |
| Green Run Reverse | |
| Red Power On | |
|
| |
| Green AFC Run | |
E08 |
| |
Yellow AFC Fault | ||
|
| |
| Blue Hand | |
|
| |
| Yellow Auto | |
| Red Power On | |
|
| |
F08 | Green AFC Run | |
| ||
Yellow AFC Fault | ||
| ||
|
| |
| Yellow Communication | |
|
| |
| ❾ Option Cards | |
Code | Feature | |
A09 | MODBUS® Plus | |
B09 | MODBUS / UNITELWAY | |
C09 | METASYS N2 | |
D09 | Ethernet | |
E09 | LONWORKS Gateway | |
F09 | DEVICENET | |
H09 | Analog card adds 1 additional analog output, | |
2 additional logic inputs, 1 additional logic output, | ||
| and 1 differential analog input. | |
|
|
| ❿ Miscellaneous Options |
A10 | Line Reactor nominal 5% impedance |
B10 | Line Contactor |
C10 | |
D10 | Omit Keypad |
E10 | Smoke Purge Relay |
F10 | (Reserved) |
G10 | cUL Listing |
H10 | Seismic Certification |
J10 | |
K10 | Additional N.O. Auxiliary Drive Run Contact |
L10 | Additional N.C. Auxiliary Drive Fault Contact |
M10 | 1 N.O. Auxiliary Bypass Run Contact |
N10 | (Reserved) |
O10 | 1 N.O. Auxiliary Auto Mode Contact |
P10 | AFC Fault Reset |
Q10 | |
R10 | Auto Transfer to Bypass |
S10 | Motor Elapsed Time Meter |
T10 | Emergency Stop |
U10 | Motor Space Heater Sequencing |
V10 | Seal Water Solenoid |
W10 | Check Valve Sequencing |
X10 | (Reserved) |
Y10 | (Reserved) |
Z10 | 24 Vdc Power Supply |
110 | Additional Control Power VA |
210 | (Reserved) |
310 | Order Engineered Special (internal use only) |
410 | RFI Suppressor |
510 | Permanent Wire Marker Sleeves |
610 | I.D. Engraved Nameplates |
710 | Harmonic Filter Provisions |
810 | (Reserved) |
910 | Barriered Bypass Enclosure |
|
|
❿Miscellaneous Options
Code Feature