Chapter 6: Configuration
Logging: Specify the logging operation of this port. The allowed values are:
Enabled: Frames received on the port are stored in the System Log.
Disabled: Frames received on the port are not logged.
The default value is “Disabled.”
NOTE: The system log memory size and logging rate is limited.
Shutdown: Specify the shutdown operation of this port. The allowed values are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled.
The default value is “Disabled.”
State: Specifies the port state. The allowed values are:
Enabled: Open port by changing the volatile port configuration of the ACL user module.
Disable: Close port byc changing the volatile port configuration of the ACL user module.
The default is “Enabled.”
Counter: Count the number of frames that match this ACL.
Buttons:
Save: Click to save changes.
Reset: Click to undo any changes made locally and revert to previously saved values.
Upper right icon (Refresh, clear): Click on the “Refresh” icon to refresh the ACL Port Configuration or click on Clear to clear them manually.
6.2.2 Rate Limiters
The section describes how to configure the switch’s ACL rate limiter parameters. Users can set the rate limiter value level in pps or kbps units.
Web Interface
To configure ACL Rate Limiter in the web interface:
1.Click “Configuration,” “ACL,” then “Rate Limiter.”
2.Specify the rate field and the range from 0 to 3276700.
3.Scroll through the units in pps or kbps.
4.Click on the “Save” button to save the setting.
5.To cancel the setting, click on the “Reset” button. The settings will revert to previously saved values.
Page 50 | LGB5028A User‘s Manual | |
|
|