5 Replacing an interface module
BigIron RX# show logging
Syslog logging: enabled (3 messages dropped, 4 flushes, 0 overruns) Buffer logging: level ACDMEINW, 560 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error I=informational N=notification W=warning
Static Log Buffer:
Jan 25 17:22:39:A:Power Supply 1 , 1st from left (top row), bad
Jan 21 14:05:34:A:Power Supply 2 , 2nd from left (top row), bad
Jan 21 14:05:34:A:Power Supply 3 , 3rd from left (top row), bad
Jan 21 14:05:34:A:Power Supply 6 , 2nd from left (bottom row), bad
Jan 21 14:05:34:A:Power Supply 7 , 3rd from left (bottom row), bad
Jan 21 14:05:36:I:System: bad i2c access (GIEI = set), Severity Minor, Mux 0x70, Channel 5, Addr 0x22 (FANTRAY3)
Jan 21 14:05:36:I:System: last good i2c access, Mux index 0x70, channel 6, Addr 0xc (PS5)
Modification to show chassis command outputs
If the system detects a major severity I2C failure, then the output from the show chassis command will change to prevent the management module from accessing devices through the I2C serial bus.
The following is an output from the show chassis command when the GIEI is set to major severity:
BigIron | RX# show chassis |
| *** | ||
*** Note: |
|
| |||
*** | Global I2C Error | Indicator is set (severity: Major). *** | |||
*** | All | I2C accesses | are | skipped. | *** |
==========================================================================
*** BigIron
Slot
Slot3 pri=1 module
Slot12 pri=1 module
--- TEMPERATURE READINGS ---
Fans are in auto mode (current speed is LOW (50%)). Temperature monitoring poll period is 60 seconds.
==========================================================================
Replacing an interface module
You can remove an interface module and replace it with a new one while the BigIron RX Series chassis is powered on and running.
104 | Brocade BigIron RX Series Hardware Installation Guide |
|