2 Installing a BigIron RX-16 switch

3. Snap the cord-retainer over the power plug to hold it in place.

FIGURE 35 Connecting a power cord to the power supply in a BigIron RX-16 chassis

 

 

 

1

 

 

 

2

 

 

 

3

 

5

 

 

 

 

4

 

1

Lift handle

4

Ground point

2

Cord retainer

5

Lift handles

3

Power cord

 

 

DANGER

If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device.

4.For information about powering on the system, refer to “Powering-on the power source” on page 55.

Connecting DC power to a BigIron RX-16 chassis

You can use a DC power source for the BigIron RX-16 chassis. This is supported through use of a DC-to-DC power supply. DC power must be supplied at 48 V and 30 A. The DC-to-DC supply provides the DC power to the chassis at 12 V and 100 A.

DANGER

The procedure in this section is for qualified service personnel.

52

Brocade BigIron RX Series Hardware Installation Guide

 

53-1002483-03

Page 64
Image 64
Brocade Communications Systems S3-1002483-03 manual Connecting DC power to a BigIron RX-16 chassis