Managing the BigIron RX Series chassis

 

 

---POWERS ---

 

 

AC Powers Are Used.

 

 

Power 1: Installed (OK)

 

 

Power 2: not present

 

 

Power 3: not present

 

 

Slot Power-On Priority:

 

 

Slot1 (pri=1)

 

 

Slot2 (pri=1)

 

 

Slot3 (pri=1)

 

 

Slot4 (pri=1)

 

 

--- FANS ---

 

 

Right Fan Tray: Fan 5: Status = OK, Speed = LOW (50%) (RPM 3333)

 

 

Right Fan Tray: Fan 6: Status = OK, Speed = LOW (50%) (RPM 3409)

 

 

--- TEMPERATURE READINGS ---

 

 

Active Mgmt Module: 32.500C 54.625C (CPU)

 

 

SNM1: 27.5C

 

 

SNM2: 30.5C

 

 

SNM3: 30.5C

 

 

LP2 Sensor1: 41.0C

 

 

Temperature Monitoring Poll Period is 60 seconds

 

 

--- MISC INFO ---

 

 

Backplane EEPROM MAC Address: 000a.80a0.2000

 

 

The display shows the following information:

 

 

TABLE 17

Chassis status and temperature information

 

 

 

 

 

 

This field...

Displays...

 

 

 

 

 

 

Powers

 

Power

BigIron RX-4: 1 – 3

BigIron RX-8: 1 – 4

BigIron RX-16: 1 – 8

Indicates whether an AC power supply is installed in the specified power supply slot and the status of the power supply, which can be one of the following:

Installed (OK) – The power supply is functioning properly and supplying power to the chassis and installed modules.

Failed – The power supply is not functioning and is not supplying power to the chassis and installed modules.

Not present – There is no power supply installed in the slot.

Slot Power-On Priority

The configured power-on priority of each interface modules installed in a

 

chassis slot.

Slot1 – Slot16

BigIron RX-4: Slot1 – Slot4

BigIron RX-8: Slot1 – Slot8

BigIron RX-16: Slot1 – Slot16

The priority of each chassis slot as configured by the lp-slot-prioritycommand. The priority can be 1 – 8, where 1 is the lowest priority and 8 is the highest priority. (The default priority is 1.) If the supply of power to the chassis falls below a minimum threshold, the chassis slots with the lowest priority will likely lose power. For information about using the lp-slot-prioritycommand, refer to “Changing priority of chassis slots for interface modules” on page 95.

Fans

Fan <number>

Information about fans in the BigIron RX Series chassis.

 

 

Status

The status of a fan can be one of the following:

 

OK – The fan is functioning properly and is keeping the temperature of

 

each module within an acceptable temperature range.

 

Failed – The fan is not functioning properly or the fan control module

 

cannot control the fan.

80