4 | Managing the BigIron RX Series chassis | ||
|
| ||
|
| AC Powers Are Used. | |
|
| Power 1: Installed (OK) | |
|
| Power 2: not present | |
|
| Power 3: not present | |
|
| Slot | |
|
| Slot1 (pri=1) | |
|
| Slot2 (pri=1) | |
|
| Slot3 (pri=1) | |
|
| Slot4 (pri=1) | |
|
| ||
|
| Right Fan Tray: Fan 5: Status = OK, Speed = LOW (50%) (RPM 3333) | |
|
| Right Fan Tray: Fan 6: Status = OK, Speed = LOW (50%) (RPM 3409) | |
|
|
| |
|
| Active Mgmt Module: 32.500C 54.625C (CPU) | |
|
| SNM1: 27.5C | |
|
| SNM2: 30.5C | |
|
| SNM3: 30.5C | |
|
| LP2 Sensor1: 41.0C | |
|
| Temperature Monitoring Poll Period is 60 seconds | |
|
| ||
|
| Backplane EEPROM MAC Address: 000a.80a0.2000 | |
|
| The display shows the following information: | |
|
| TABLE 17 | Chassis status and temperature information |
|
|
|
|
|
| This field... | Displays... |
|
|
|
|
|
| Powers |
|
Power
BigIron
BigIron
BigIron
Indicates whether an AC power supply is installed in the specified power supply slot and the status of the power supply, which can be one of the following:
•Installed (OK) – The power supply is functioning properly and supplying power to the chassis and installed modules.
•Failed – The power supply is not functioning and is not supplying power to the chassis and installed modules.
•Not present – There is no power supply installed in the slot.
Slot | The configured |
| chassis slot. |
Slot1 – Slot16
BigIron
BigIron
BigIron
The priority of each chassis slot as configured by the
Fans
Fan <number> | Information about fans in the BigIron RX Series chassis. |
|
|
Status | The status of a fan can be one of the following: |
| • OK – The fan is functioning properly and is keeping the temperature of |
| each module within an acceptable temperature range. |
| • Failed – The fan is not functioning properly or the fan control module |
| cannot control the fan. |
80 | Brocade BigIron RX Series Hardware Installation Guide |
|