Hardware features | 1 |
FIGURE 14 Rear fan component locations for the BigIron RX-16
1
1 Fan modules
Upon system startup, the fans in the BigIron RX Series switches operate at high speed, then the management module lowers the fan speed to low speed.
By default, the BigIron RX Series switch polls the temperature sensor on each module every 60 seconds to get a temperature reading. Depending on the temperature readings for the modules, the system can do the following:
•Leave the fan speed as is
•Increase the fan speed
•Decrease the fan speed
•Shut down a module to prevent damage
If the temperature of a module exceeds specified high temperature thresholds, the system generates a Syslog message and SNMP trap. The system can also shut the module down if the temperature exceeds the highest threshold.
LEDs
The fan control modules include a
Brocade BigIron RX Series Hardware Installation Guide | 19 |
|