6 Upgrading images independently

If you want to retain the IronWare images in the interface module’s code flash, enter the lp cont-bootno-sync<slot-number> command at the Privileged EXEC prompt.

After the management module finishes booting, do the following:

Enter the show module command at any CLI level, and verify that the status of all interface modules is CARD_STATE_UP.

Enter the show version command at any CLI level, and verify that all management and interface modules are running the new software image version.

If you find that an interface module is in a waiting state or is running an older software image, then you may have forgotten to enter the lp cont-boot sync <slot-number> command at the Privileged EXEC prompt.

Upgrading the MBRIDGE FPGA on the management module

BigIron RX Series management modules contain an upgradable FPGA image called MBRIDGE.

The MBRIDGE image installed must be compatible with the software version you are running on the BigIron RX Series. Refer to the Software Release Notes for compatibility information.

NOTE

You will not need to upgrade the MBRIDGE FPGA image with every Multi-Service software upgrade. Only upgrade this image if specified in the release notes.

Overview of tasks in the FPGA image upgrade process

Follow the steps given below to upgrade the MBRIDGE FPGA image on a BigIron RX Series management module.

1.Determine the versions of the images currently installed on the BigIron RX Series management module.

For information about performing this task, refer to “Determining the MBRIDGE image versions” on page 140.

2.Copy the new image from a source to a destination.

The source from which to copy the new image is usually a TFTP server to which the BigIron RX Series system has access or a flash card in the management module’s slot 1 or 2. The destination to which to copy the new image is all or one specified interface module.

For information about performing this task, refer to “Upgrading the MBRIDGE FPGA image” on page 141.

3.Reboot the interface module upon which you upgraded the MBRIDGE images.

Determining the MBRIDGE image versions

To display the versions of the MBRIDGE images currently installed on the Gigabit Ethernet modules, enter the show version command at any level of the CLI:

BigIron RX> show version

.

.

140

Brocade BigIron RX Series Hardware Installation Guide

 

53-1002483-03

Page 152
Image 152
Brocade Communications Systems S3-1002483-03 manual Upgrading the Mbridge Fpga on the management module