2 Installing a BigIron
NOTE
To provide better grounding of the chassis to the rack, attach the chassis to the rack using star washers. Additionally, if any single hole grounding lugs are used star washers shall be used as a means to prevent rotation of the lug.
6.Add additional screws as required.
7.Repeat step 2 through step 6 to mount each subsequent chassis in the same rack.
Removing the slot blanks
The BigIron
CAUTION
If you do not install a module in a slot, you must keep the slot blank in place. If you run the chassis with an uncovered slot, the system may overheat. Tighten the screws that secure the slot blanks so that they remain in place when removing adjacent panels or modules.
Although the slot blanks are different in size, the procedure for removing them from the BigIron
You will need a
1.Loosen the screws on either end of the slot blank by hand or with a
2.Pull the slot blank out of the chassis, and store it in a safe place for future use.
Installing BigIron RX-4 modules
This section provides one procedure that applies to all modules. The sequence for installing more than one module is important to ensure proper fit. The recommended sequence for the BigIron
NOTE
The BigIron RX Series modules are dedicated, which means that you must install them in the BigIron RX Series chassis only. For example, if you attempt to install the BigIron RX Series management module in another Brocade chassis or a management module intended for another Brocade chassis in the BigIron RX Series chassis, the chassis and module will not function properly.
Table 10 provides the chassis slot numbers into which you must install the modules. Markings for the chassis slots appear at the base of the slots.
28 | Brocade BigIron RX Series Hardware Installation Guide |
|