Brocade Communications Systems S3-1002483-03 manual Syntax show module

Models: S3-1002483-03

1 206
Download 206 pages 54 b
Page 74
Image 74

2 Verifying proper operation

If you do not see this prompt, do the following.

1.Make sure the cable is securely connected to your PC or terminal and the Console port or Ethernet port.

2.Check the settings in your terminal emulation program. In addition to the session settings listed in “Attaching a PC or terminal to the Console port or Ethernet port” on page 54, make sure the terminal emulation session is running on the same serial port you attached to the Console port.

If you see this prompt (BigIron RX>), you are now connected to the system and can display the status of the modules using the CLI. Enter the following command at any CLI level:

BigIron RX#

show module

Status

Ports

Starting MAC

Module

M1 (upper): BigIron RX Mgmt Module

Active

 

 

M2 (lower):

RX Switch Fabric Module

Active

 

 

F0: BigIron

 

 

S1:

 

 

 

 

S2:

 

 

 

 

S3:

RX 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S4: BigIron

S5: BigIron

RX 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S6: BigIron

RX 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S7:

 

 

 

 

S8:

 

 

 

 

Syntax: show module

The Status column shows the module status. A management module can have one of the following statuses:

ACTIVE – The module is currently the active management module.

STANDBY – The module is currently the standby management module.

COMING UP – The module is coming up as the standby module. This status occurs if the standby management module becomes the active module, which is called a switchover.

The switch fabric module can have one of the following statuses:

ACTIVE – The module is up and running.

BAD – The management module cannot initialize the switch fabric module.

An interface module can have one of the following statuses:

CARD_STATE_INIT – The system detects the module but the module is not up and running yet.

CARD_STATE_BOOT – The module is booting.

CARD_STATE_INTERACTIVE – The module is booting from interactive mode.

CARD_STATE_LP_SYNC – The module’s IronWare images are synchronized between the management module and interface module.

CARD_STATE_SYNC – The system is currently synchronizing the module’s IronWare images between the management module and interface module.

CARD_STATE_SOFTWARE_LOADED – The module has loaded its IronWare image.

CARD_STATE_POWER_OFF – The module does not have power.

CARD_STATE_UP – The module is up and operating normally.

62

Brocade BigIron RX Series Hardware Installation Guide

 

53-1002483-03

Page 74
Image 74
Brocade Communications Systems S3-1002483-03 manual Syntax show module