Managing the BigIron RX Series chassis

 

 

 

TABLE 18

Syslog buffer configuration (Continued)

 

 

 

 

 

 

 

This field...

 

Displays...

 

 

 

 

 

 

 

overruns

 

The number of times the dynamic log buffer has filled up and been

 

 

 

 

cleared to hold new entries. For example, if the buffer is set for 100

 

 

 

 

entries, the 101st entry causes an overrun. After that, the 201st entry

 

 

 

 

causes a second overrun.

 

 

 

 

 

 

 

level

 

The message levels that are enabled. Each letter represents a message

 

 

 

 

type and is identified by the key (level code) below the value. If you

 

 

 

 

disable logging of a message level, the code for that level is not listed.

 

 

 

 

 

 

messages logged

The total number of messages that have been logged since the software

 

 

 

 

was loaded.

 

 

 

 

 

 

 

level code

 

The message levels represented by the one-letter codes.

 

 

 

 

 

Static and dynamic buffers

The software provides two separate buffers:

Static – Logs power supply failures, fan failures, and temperature warning or shutdown messages.

Dynamic – Logs all other message types.

In the static log, new messages replace older ones, so only the most recent message is displayed. For example, only the most recent temperature warning message will be present in the log. If multiple temperature warning messages are sent to the log, the latest one replaces the previous one. The static buffer is not configurable.

The message types that appear in the static buffer do not appear in the dynamic buffer. The dynamic buffer contains up to the maximum number of messages configured for the buffer (50 by default), then begins removing the oldest messages (at the bottom of the log) to make room for new ones.

The static and dynamic buffers are both displayed when you display the log.

BigIron RX(config)# show logging

...

Static

Log Buffer:

 

6, 1st right, failed

Aug 27

12:42:42:A:Power Supply

Dynamic Log Buffer (50 lines):

 

Aug 27

12:19:04:I:Interface

ethernet3/4, state up

Aug 27

12:19:04:I:Interface

ethernet6/3, state up

Aug 27

12:19:04:I:Interface

ethernet3/2, state up

Aug 27

12:19:04:I:Interface

ethernet6/1, state up

Aug 27

12:19:00:N:Module up

in

slot 6

Aug 27

12:19:00:N:Module up

in

slot 3

Aug 27

12:18:43:I:Warm start

 

 

When you clear log entries, you can selectively clear the static or dynamic buffer, or you can clear both. For example, to clear only the dynamic buffer, enter the following command at the Privileged EXEC level:

BigIron RX# clear logging dynamic-buffer

Syntax: clear logging [dynamic-buffer static-buffer]