1 Hardware features

Figure 10 shows the switch fabric module’s front panel.

FIGURE 10 Switch fabric module front panel

Pwr

Active

BI-SWF

The front panel includes two LEDs, which Table 7 describes.

TABLE 7

Switch fabric module LEDs

 

 

 

 

 

LED

Position

State

Meaning

 

 

 

 

Pwr

Above Active LED

On

The module is receiving power.

 

 

 

 

 

 

Off

The module is not receiving power.

 

 

 

 

Active

Below Pwr LED

On

The chassis switch fabric is active and ready

 

 

 

to switch user packets.

 

 

 

 

 

 

Off for an extended

The chassis switch fabric is not active and

 

 

period

cannot switch user packets.

 

 

 

 

Power supplies

The BigIron RX Series switches support the following power supply options:

BigIron RX-4: Accommodates three power supplies (AC or DC) with one required and two redundant. It is shipped with one power supply. You must purchase one or two additional power supplies if you want your BigIron RX-4 equipped for redundancy.

BigIron RX-8: Accommodates four power supplies (AC or DC) with two required and two redundant. Because power is supplied over a common power bus, any power supply purchased in addition to the two required will provide backup for any supply that fails. Equipping a BigIron RX-8 with two additional power supplies provides full redundancy for both of the required power supplies.

BigIron RX-16: Accommodates eight power supplies (AC or DC) with four required and four redundant. Because power is supplied over a common power bus, any power supply purchased in addition to the four required will provide backup for any supply that fails. Equipping a BigIron RX-16 with four additional power supplies provides full redundancy for all of the required power supplies.

In the BigIron RX-8, and BigIron RX-16, you install the power supplies (AC or DC) in the slots along the bottom of the chassis. In the BigIron RX-4, the power supplies (AC or DC) are installed in slots in the rear of the chassis.The installed power supplies provide power to all chassis components, sharing the workload equally and reporting their status to the management module. If the management module detects that one of these power supplies has failed or overheated, the management module will redistribute the failed power supply’s workload to the remaining power supplies.

16

Brocade BigIron RX Series Hardware Installation Guide

 

53-1002483-03

Page 28
Image 28
Brocade Communications Systems S3-1002483-03 manual Power supplies, Shows the switch fabric module’s front panel