Upgrading images independently | 6 |
•The total time it takes for the hitless upgrade process to finish varies between approximately 1 and 10 minutes. This depends on the size of the MAC table, the number of OSPF and BGP neighbors and the size of the routing table. Router configuration is unavailable during the entire hitless upgrade process. The message
•The active management module changes from the initial active management module to the standby management module during the hitless upgrade process. This makes it necessary to have a connection to the console interface on both management modules.
•Upon being reset, the management and interface module CPUs are unable to send and receive any packets. Once the management and interface modules are up and running, their CPUs are able to send and receive packets, even before the hitless upgrade process is complete.
•Router configuration is not allowed to be changed during the entire hitless upgrade process.
•
•FPGA images cannot be upgraded using the hitless upgrade process.
•This feature cannot be used to downgrade an image to an older major version than the version that the device is currently running.
•If there are protocol dependencies between neighboring nodes, it is recommended that only each node is upgraded: one node at a time.
•After hitless upgrade, the BigIron RX router will still have the same running configuration as it does before the upgrade. A configuration that is not saved before hitless reload is not removed and the existing startup configuration does not take effect. This behavior is the same as displayed by the management module switchover feature.
NOTE:
•Hitless upgrade is only supported from version 2600c or later 2600x patch releases and hitless downgrade to version 2600c or later 2600x patch releases.
•Due to Internal changes introduced in patch release version 02.6.00c, hitless upgrade is not supported on 02.6.00c and hitless downgrade is not supported from 02.6.00c.
•Due to Internal changes introduced in patch release version 02.3.00e, users cannot perform a hitless upgrade from earlier 02.3.00 versions to 2.3.00f or higher versions.
•Due to Internal changes introduced in patch release version 02.3.00f, users cannot perform a hitless upgrade from earlier 02.3.00 versions to 02.3.00g or higher versions.
•The hitless upgrade feature is not supported on release 02.5.00b to 02.5.00c for the BigIron
The hitless OS software process
Follow the steps given below to perform hitless upgrade of
1.Version 02.3.00 or later of the
2.The
3.The hitless upgrade process is begun on the active management module which initiates the upgrade process on the standby management module.
Brocade BigIron RX Series Hardware Installation Guide | 143 |
|