Managing the cooling system | 4 |
Syntax:
For the <module> parameter, you can specify the following:
•lp – Changes low and high temperature thresholds for the interface modules.
•mp – Changes low and high temperature thresholds for the active and standby management modules.
•
•switch fabric – Changes low and high temperature thresholds for the switch fabric module.
For the
For example, if you are changing the temperature thresholds for a management module’s high and
BigIron RX(config)#
BigIron RX(config)#
However, the BigIron RX Series system will not accept the following values because the low temperature threshold being entered for the high speed (77× C) is higher than the high temperature threshold (76× C) for the
BigIron RX(config)#
BigIron RX(config)#
Displaying temperature thresholds for modules and fan speeds
To check the current settings of the low and high temperature thresholds for modules and fan speeds, you can enter the following command at any level of the CLI:
BigIron RX# show
=== Thermal Sensor | Control Block (THERMAL_SENSOR_TEST_RULE_MP) === | |||
Fan Speed | Low: | - 60 |
| |
Fan Speed | Med: 57 | - 70 | 80 | |
Fan Speed | 67 - | |||
Fan Speed | Hi: 77 - | 85 |
| |
state = 0 | (FAN_STATE_LOW) | |||
max_ts_shut_off_count = 3 | ||||
shut_off_count = 0 | 0 0 | 0 0 0 0 0 0 0 0 0 0 0 0 0 | ||
=== Thermal Sensor | Control Block (THERMAL_SENSOR_TEST_RULE_SNM) === | |||
Fan Speed | Low: | - 60 |
| |
Fan Speed | Med: 57 | - 70 | 80 | |
Fan Speed | 67 - | |||
Fan Speed | Hi: 72 - | 85 |
| |
state = 0 | (FAN_STATE_LOW) | |||
max_ts_shut_off_count = 3 | ||||
shut_off_count = 0 | 0 0 | 0 0 0 0 0 0 0 0 0 0 0 0 0 | ||
=== Thermal Sensor | Control Block (THERMAL_SENSOR_TEST_RULE_LP) === | |||
Fan Speed | Low: | - 50 |
| |
Fan Speed | Med: 46 | - 55 |
|
Brocade BigIron RX Series Hardware Installation Guide | 85 |
|