Brocade BigIron RX Series Hardware Installation Guide 33
53-1002483-03
Installing a BigIron RX-4 switch 2
1. Use a flat-blade screwdriver to remove the two screws holding the transparent cover over the
power supply lugs.
FIGURE 21 The BigIron RX-4 DC power supply
2. Use a Phillips head screwdriver to remove each of the power lugs.
3. Crimp #8 AWG power supply wire into the power lugs and reconnect the power lugs to the
power supply unit.
FIGURE 22 Crimping the power supply wire in the lug
4. Re-attach the transparent cover over the power supply lugs that was removed in step 1.
5. Connect the wire to your DC power source making sure to connect the -48V cabl e to the
negative terminal on the power supply and the 0V cable to the positive terminal.
Final steps
Follow the steps listed below to complete the installation:
“Attaching a management station”
“Powering-on the power source”
“Verifying proper operation”
1 Screws holding power lugs 2 Screws holding transparent cover
1 #8 AWG power supply wire
DC
IN
DC
OK
ALM
1
2
1