2 Verifying proper operation
TABLE 13 Desired and abnormal LED states after system power on (Continued)
LED | Desired state | Meaning | Abnormal | Meaning or action |
|
|
| state |
|
|
|
|
|
|
DC OK | Green (steady) | The power supply is | Off | The power supply is not supplying |
|
| providing DC power to |
| power to the chassis. If the AC OK |
|
| the BigIron RX Series |
| LED is lit Green, then there is a |
|
| chassis. |
| problem with the power supply |
|
|
|
| and it must be replaced. |
|
|
|
|
|
ALM | ALM | The power supply is in | Amber | The power supply is |
|
| normal operating |
| malfunctioning. |
|
| condition. |
|
|
|
|
|
| |
Power supplies DC |
|
|
| |
|
|
|
|
|
DC IN | Green (steady) | The power supply is | Off | The power supply is not receiving |
|
| receiving DC power |
| power from a DC power source You |
|
| from a DC power |
| can do the following: |
|
| source. |
| • Make sure that the power |
|
|
|
| supply cables are connected |
|
|
|
| securely to the power source |
|
|
|
| and the power supply. |
|
|
|
| • Make sure that the DC power |
|
|
|
| source is 48 VDC @ 30 A |
|
|
|
| (Operating voltage range is |
|
|
|
| |
|
|
|
| • Make sure that the power |
|
|
|
| source has power. |
|
|
|
|
|
DC OUT | Green (steady) | The power supply is | Off | The power supply is not supplying |
|
| providing DC power to |
| power to the chassis. If the DC IN |
|
| the BigIron RX Series |
| LED is lit Green, then there is a |
|
| chassis. |
| problem with the power supply |
|
|
|
| and it must be replaced. |
|
|
|
|
|
ALM | Off | The power supply is in | Amber | The power supply is |
|
| normal operating |
| malfunctioning. |
|
| condition. |
|
|
60 | Brocade BigIron RX Series Hardware Installation Guide |
|