Verifying proper operation

2

TABLE 13 Desired and abnormal LED states after system power on (Continued)

LED

Desired state

Meaning

Abnormal

Meaning or action

 

 

 

state

 

 

 

 

 

 

Link

On

A link is established

Off

At this stage of the installation,

 

 

with the remote port.

 

you have not yet cabled the

 

 

 

 

interface module ports, so this

 

 

 

 

LED will be off.

 

 

 

 

After cabling this port, if this LED

 

 

 

 

is off, a link is not established with

 

 

 

 

the remote port. For more

 

 

 

 

information, refer to Table 15 on

 

 

 

 

page 75.

 

 

 

 

 

Active

On or blinking

The port is

Off for an

At this stage of the installation,

 

 

transmitting and

extended

you have not yet cabled the

 

 

receiving user packets.

period.

interface module ports, so this

 

 

 

 

LED will be off.

 

 

 

 

After cabling this port, if this LED

 

 

 

 

is off, the port is not transmitting

 

 

 

 

or receiving user packets. For

 

 

 

 

information about action you can

 

 

 

 

take to troubleshoot the problem,

 

 

 

 

refer to Table 15 on page 75.

Switch fabric module

Pwr

On

The module is

Off

The module is not receiving power.

 

 

receiving power.

 

You can do the following:

 

 

 

 

If using AC power supplies,

 

 

 

 

see the entry for the AC

 

 

 

 

power supply LED in this

 

 

 

 

table for more information.

 

 

 

 

 

Active

On

The switch fabric

Off for an

The switch fabric module is not

 

 

module is active and

extended

active and user packets are not

 

 

ready to switch user

period.

being switched from one interface

 

 

packets.

 

module to another.

 

 

 

 

You must replace the switch fabric

 

 

 

 

module. For information about

 

 

 

 

performing this task, refer to

 

 

 

 

“Replacing a switch fabric

 

 

 

 

module” on page 109.

 

 

 

 

 

Power supplies AC

 

 

 

 

 

 

 

 

 

AC OK

Green (steady)

The power supply is

Off

The power supply is not receiving

 

 

receiving AC power

 

power from an AC power source

 

 

from an AC power

 

You can do the following:

 

 

source.

 

Make sure that the power

 

 

 

 

supply cord is connected

 

 

 

 

securely to the wall outlet

 

 

 

 

and the power supply.

 

 

 

 

Make sure that the wall

 

 

 

 

outlet is rated for 115/120V

 

 

 

 

and 20A. If it is not, obtain a

 

 

 

 

cable that is compatibly rated

 

 

 

 

for the outlet.

 

 

 

 

Make sure that the wall

 

 

 

 

outlet has power.

Brocade BigIron RX Series Hardware Installation Guide

59

53-1002483-03

 

Page 71