Installing a BigIron | 2 |
Before installing a module in the BigIron
•An ESD wrist strap with a plug for connection to the ESD connector on the BigIron
DANGER
For safety reasons, the ESD wrist strap should contain a 1 meg ohm series resistor.
•A large
Follow the steps given below to install a module in the BigIron
1.Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on the chassis front.
2.Remove the module from its packaging.
3.With the ejectors in the outward position, insert the module into the appropriate chassis slot and slide the card along the card guide until the ejectors on either side of the module move close to the module front panel.
FIGURE 26 Installing a module in a BigIron RX-8 chassis
1
1 Management module
NOTE
When inserting the module into the chassis, make sure that the faceplate does not overlap with the faceplate of an adjacent interface module.
4.Push the ejectors in until they are flush with the module front panel. This action will fully seat the module in the backplane. Modules have a snug fit for maximum EMI protection.
NOTE
The installation instructions for installing modules shown in the following illustrations are exactly the same for interface, management, and switch fabric modules.
5.Tighten the two screws at either end of the module front panel by pushing them in and turning them clockwise. Then, tighten the screws further using the
Brocade BigIron RX Series Hardware Installation Guide | 39 |
|