6 Upgrading images independently

4.The standby management module is reset.

5.The active management module is reset and the standby management module assumes control as the active module.

6.Active console control is lost to the previously active management module as it becomes the standby management module.

7.The active management module initiates the upgrade process on all interface modules.

8.The router is now operating on the new Multi-Service IronWare software. The management module that was initially configured as the standby management module is now the active management module and the management module that was initially configured as the active management module is now the standby.

Figure 49 provides a detailed diagram of the Hitless reload process.

FIGURE 49 Management module (MP) and interface module (LP) hitless upgrade process

Original

New

 

Active

 

Active

LPs

MP

 

 

MP

 

 

 

hitless-reload command

Reset Standby MP

 

 

performed at console

 

 

 

MP Sync Done

Reset

 

 

 

 

 

SW info

 

 

 

request/acknowledge

 

 

Reset

Switchover

 

 

 

MP Sync Done

 

 

 

 

LP SW info reset

 

 

 

LP module up

 

 

 

LP module L2, L3, L4 done?

 

 

 

LP module L2, L3, L4

 

 

 

done response

 

Reset Reset

Performing a hitless OS software upgrade,

To perform a hitlessLayer 2 OS software upgrade, you must perform the following tasks:

Copy version 02.3.00 or later of the Multi-Service IronWare software to the primary and secondary image on both the active and standby management modules and interface modules.

Setup a console connection to both the active and standby management modules. These connections can be through a telnet, SSH, or serial console session.

Type the hitless-reloadcommand at the console of the active management module.

144

Brocade BigIron RX Series Hardware Installation Guide

 

53-1002483-03

Page 156
Image 156
Brocade Communications Systems S3-1002483-03 manual Performing a hitless OS software upgrade