Brocade Communications Systems S3-1002483-03 manual Removing an interface module

Models: S3-1002483-03

1 206
Download 206 pages 54 b
Page 117
Image 117

Replacing an interface module

5

NOTE

A BigIron RX Series interface module is dedicated, which means that you must install it in the BigIron RX Series chassis only. If you attempt to install a BigIron RX Series interface module in another Brocade chassis or an interface module intended for another Brocade chassis in the BigIron RX Series chassis, the chassis and interface module may not function properly.

CAUTION

If hot removing or inserting a module, please allow a minimum of two seconds after a module (or power supply or fan tray) has been removed before inserting a module in the same slot.

This section provides information about the following tasks:

Removing an interface module

Installing a new interface module

Removing an interface module

You can remove an interface module while the BigIron RX Series chassis is powered on and running.

Before removing an interface module from the BigIron RX Series chassis, you must disable the module, which prevents the remaining interface modules in the chassis from dropping user packets.

To perform this task, you must have the following on hand:

An ESD wrist strap with a plug for connection to the ESD connector on the BigIron RX Series chassis.

DANGER

For safety reasons, the ESD wrist strap should contain a 1 meg ohm series resistor.

A large flat-head screwdriver.

Follow the steps given below to remove an interface module from the BigIron RX Series chassis.

1.Disable the module by entering the power-off lp <slot-number> command at the Privileged EXEC level of the CLI. For the <slot-number> parameter, specify 1 – 4 for BigIron RX-4, 1 – 8 for BigIron RX-8 or 1 – 16 for BigIron RX-16.

2.Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector located in the upper right corner of the chassis front.

3.Using the flathead screwdriver if necessary, loosen the two screws on the ends of the module.

4.Pull the card ejectors towards you, and away from the module front panel. This action unseats the module from the backplane.

5.Pull the module out of the chassis, and place in an anti-static bag for storage if desired.

6.Install a new module in the slot. For information about performing this task, refer to “Installing a new interface module”.

Brocade BigIron RX Series Hardware Installation Guide

105

53-1002483-03

 

Page 117
Image 117
Brocade Communications Systems S3-1002483-03 manual Removing an interface module