Using unified software images to upgrade images | 6 |
The
The
The
The
The
Using unified software images to upgrade images
Beginning with version 02.5.00 and later of the
•The boot images no longer need to be upgraded with each release and in fact will almost never need to be changed. This eliminates one extra step in the upgrade process, thus simplifying the upgrade procedure, reducing the chance of operator error and leading to a faster upgrade process.
•The Monitor image no longer needs to be upgraded with each release. In release 02.5.00, all OS functions have been moved out of the Monitor image into the IronWare image. This has simplified the Monitor image and it no longer needs to be upgraded every time, thus eliminating another step in the upgrade process.
•The first version of the boot and monitor image supporting this separation is 02.5.00.
Unified software image upgrade to upgrade release 02.6.00 and later
BigIron RX software release 02.2.01 and later can be upgraded using the Unified Software Image Upgrade procedure. When copying the image, you must load the
NOTE
Failure to load the
1. Copy the unified software image (rx02702h.bin) from a TFTP server to the switch.
For example, to copy the entire unified software image, the
BigIron RX# copy tftp image 10.10.12.12 rx02702h.bin
Syntax: copy tftp image
Brocade BigIron RX Series Hardware Installation Guide | 133 |
|