126 Brocade BigIron RX Series Hardware Installation Guide
53-1002483-03

Displaying flash memory and version information

6
Compiled on Oct 20 2007 at 00:05:04 labeled as rlp02500
o IronWare Image (Secondary)
Version 2.5.0T157, Size 1999406 bytes, Check Sum 04f4
Compiled on Oct 10 2007 at 17:15:40 labeled as rlp02500
o Boot-Monitor Image
Version 2.5.0T155, Size 285248 bytes, Check Sum 5643
Compiled on Oct 19 2007 at 23:08:32 labeled as rlb02500
Boot Flash: Type AM29LV040B, Size 512 KB
o Boot-Monitor Image
Version 2.5.0T155, Size 285248 bytes, Check Sum 5643
Compiled on Oct 19 2007 at 23:08:32 labeled as rlb02500
====================================================================
.
.
.
====================================================================
All show flash done
TABLE 2 3 Code flash and boot flash information
This field... Displays...
Management modules
<type> Management Module
(<location>)
The management module for which flash information is displayed.
The <type> parameter indicates an active or standby management module.
The <location> parameter indicates the top or bottom slot (M1 or M2,
respectively).
Code Flash The model number and size of the management module’s code flash.
IronWare Image (Primary or
Secondary)
Indicates the IronWare image installed in the primary or secondary location
in the management module’s code flash. The image name format is
described in “Software image naming conventions” on page123. The
actual image name depends on the version of software you have running
on your BigIron RX Series switch.
The output displays the following information about the image:
Version – “2.3.0Txxy” indicates the image version number. The “Txxy”
is used by Brocade for record keeping. The “xx” indicates the hardware
type, while the “y” indicates the image type.
Size – The size, in bytes, of the image.
Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.
Compilation date and time – The date and time that Brocade compiled
the image.