Chapter 18 DLPs F300 to F399

DLP- F314 Provision MS-DCC Terminations

Note When MS-DCC is provisioned, an RS-DCC termination is allowed on the same port, but is not recommended. RS-DCC and MS-DCC are only needed on the same port during a software upgrade if the software version does not support MS-DCC. Changing configuration of a port having MS-DCC termination to RS-DCC termination is allowed. During this procedure both MS-DCC and RS-DCC terminations can be present on the same port. Once the RS-DCC termination is configured see “DLP-F253 Provision RS-DCC Terminations” task on page 17-45delete the MS-DCC terminations as specified in“DLP-F322 Delete an MS-DCC Termination” task on page 18-20, and enable the OSPF on RS-DCC termination if not enabled see “DLP-F319 Change an RS-DCC Termination” task on page 18-19.

Step 1 In node view, click the Provisioning > Comm Channels > MS-DCC tabs.

Step 2 Click Create.

Step 3 In the Create MS-DCC Terminations dialog box, click the ports where you want to create the MS-DCC termination. To select more than one port, press the Shift key or the Ctrl key.

Note MS-DCC refers to the multiplex section DCC, which is used for ONS 15600 SDH DCC terminations. The SDH MS-DCCs and the RS-DCC (when not used as a DCC termination by the ONS 15600 SDH) can be provisioned as DCC tunnels. See the “DLP-F244 Create a DCC Tunnel” task on page 17-36.

Step 4 In the Port Admin State area, click Set to unlocked to put the port in service.

Step 5 Verify that the Disable OSPF on DCC Link check box is unchecked.

Step 6 If the RS-DCC termination is to include a non-ONS node, check the Far End is Foreign check box. This automatically sets the far-end node IP address to 0.0.0.0, which means that any address can be specified by the far end. To change the default to a specific the IP address, see the “DLP-F320 Change an MS-DCC Termination” task on page 18-19.

Step 7 In the Layer 3 area, perform one of the following:

Check the IP box only—If the MS-DCC is between the ONS 15600 SDH and another ONS node and only ONS nodes reside on the network. The MS-DCC will use point-to-point protocol (PPP).

Check the IP and OSI boxes—If the MS-DCC is between the ONS 15600 SDH and another ONS node and third party NEs that use the OSI protocol stack are on the same network. The MS-DCC will use PPP.

Note Checking only the OSI box (LAP-D) is not available for MS-DCCs.

Step 8 If you checked OSI, complete the following steps. If you checked IP only, continue with Step 9.

a.Click Next.

b.Provision the following fields:

Router—Sets the OSI router.

ESH—Sets the End System Hello propagation frequency. End system NEs transmit ESHs to inform other ESs and ISs about the NSAPs it serves. The default is 10 seconds. The range is 10 to 1000 seconds.

 

 