18-96
Cisco ONS 15600 SDH Procedure Guide, R8.0
October 2007
Chapter18 DLPs F300 to F399
DLP- F384 Install the ASAP 1PIO and 4PIO (PIM) Modules
Figure18-22 1PIO Module Faceplate
Figure 18-23 shows the 4PIO module faceplate.
Figure18-23 4PIO Module Faceplate
Note The LEDs located on the 1PIO and 4PIO will not light until a fixed rate SFP/XFP (PPM) is
installed in the associated PPM slot or a multirate optical (MRO) PPM is installed and an optical
rate is provisioned. If the port on the PP M does not have a raised alarm, the associated LED will
be green in color (meaning the port administrative state is Unlocked-automaticInservice). If the
port has an alarm, the LED will be amber in color (meaning the administrative state is Unlocked
and a valid signal is not present).
Note If you insert a card into a slot that is provisioned for a different card, all red LEDs turn on and
you will see an MEA alarm for that slot when you open CTC.
151941
ASAP
1P IO
Hand tighten, or remove
the label to tighten using
a Phillips screwdriver
124039
ASAP
4P IO
1
2
3
4
Hand tighten, or remove
the label to tighten using
a Phillips screwdriver