Chapter 18 DLPs F300 to F399

DLP- F393 Change Threshold Settings for STM-N Ports

Step 1 On the shelf graphic, double-click the STM-16, STM-64, or ASAP card that you want to provision. The card view appears.

Step 2 As needed, complete the following:

a.Click Line, Section, Path, or Physical to provision the line, section, path, and physical options in Table 18-7for each STM-N port.

b.Change the selection to Near End/Far End, 15 Min/1Day as necessary.

c.Click Refresh to view or modify the thresholds for each selection.

Note Far End section thresholds are not available for the STM-64 card.

Table 18-7

SDH Threshold Options (Line, Section, and Path)

 

 

 

Heading

Description

Options

 

 

 

Port

Port number

1–16 for an STM-16 card, 1–4 for an STM-64

 

 

card, 1-1-1 to 4-4-1 for an ASAP port number

 

 

 

CV

Coding violations

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line, Section, or Path (Near and

 

 

Far End). Select the bullet and click Refresh.

 

 

 

ES

Errored seconds

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line, Section, or Path (Near and

 

 

Far End). Select the bullet and click Refresh.

 

 

Numeric. The defaults (15 min/1 day) are:

 

 

 

SES

Severely errored seconds

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line, Section, or Path (Near and

 

 

Far End). Select the bullet and click Refresh.

 

 

 

SEFS

Severely errored framing seconds

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Section (Near and Far End). Select

 

 

the bullet and click Refresh.

 

 

 

FC

Failure count

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line or Path (Near and Far End).

 

 

Select the bullet and click Refresh.

 

 

 

UAS

Unavailable seconds

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line or Path (Near and Far End).

 

 

Select the bullet and click Refresh.

 

 

 

PSC

Protection Switching Count (Line)

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line (Near End). Select the bullet

 

 

and click Refresh.

 

 

 

PSD

Protection Switch Duration (Line)

Numeric. Can be set for 15-minute or one-day

 

 

intervals for Line (Near End). Select the bullet

 

 

and click Refresh.

 

 

 

PSC-W

Protection Switching Count

Numeric. Can be set for 15-minute or one-day

 

(Working Line)

intervals for Line (Near End). Select the bullet

 

 

and click Refresh.

 

 

 

 

Cisco ONS 15600 SDH Procedure Guide, R8.0

18-112

October 2007

Page 112
Image 112
Cisco Systems ONS 15600 SDH manual 18-112