Chapter 18 DLPs F300 to F399
DLP- F352 Roll One
Figure 18-16 Selecting Roll Attributes for a Single Roll onto a Second Circuit
Step 6 Click Next.
Step 7 In the Pivot/Fixed Point 1 window, click the square representing the facility that you want to keep (Figure
This facility is the fixed location in the
Step 8 Click Next.
Step 9 In the Select New End Point area, choose the Slot, Port, and VC3 or VC4 from the
Step 10 Click Finish.
The statuses of the Roll From and Roll To circuits change from DISCOVERED to ROLL_PENDING in the Circuits tab.
Step 11 Click the Rolls tab. For the pending roll, view the Roll Valid Signal status. When one of the following conditions are met, continue with Step 12.
•If the Roll Valid Signal status is true, a valid signal was found on the new port.
•If the Roll Valid Signal status is false, a valid signal was not found. Wait until the signal is found before continuing with the next step. If the signal is not found, refer to the “General Troubleshooting” chapter in the Cisco ONS 15600 SDH Troubleshooting Guide. To cancel the roll, see the
•The roll is a
Note You cannot cancel an automatic roll after a valid signal is found.
•A roll can be forced onto the Roll To Circuit destination without a valid signal by using the Force Valid Signal button. If you choose Force Valid Signal, traffic on the circuit that is involved in the roll will be dropped once the roll is completed.
|