18-60
Cisco ONS 15600 SDH Procedure Guide, R8.0
October 2007
Chapter18 DLPs F300 to F399
DLP- F352 Roll One Cross-Connect from an Optical Circuit to a Second Optical Circuit
DLP-F352 Roll One Cross-Connect from an Optical Circuit to a Second Optical Circuit
Step1 From the View menu, choose Go To Network View.
Step2 Click the Circuits tab.
Step3 Press Ctrl and click the two circuits that you want to use in the roll process.
The circuits must have a DISCOVERED status; in addition, they must be the same size and direction for
you to start a roll. The planned Roll To circuit must not carry traffic.The Roll To facility should be DCC
connected to the source node of the Roll To circuit.
Step4 From the Tools menu, choose Circuits > Roll Circuit.
Step5 In the Roll Attributes area, complete the following (Figure18-16):
a. From the Circuit Roll Mode drop-down list, choose Auto to create an automatic roll (required for a
1-way source roll) or Manual to create a manual roll (required for 1-way destination roll).
b. From the Circuit Roll Type drop-down list, choose Single to indicate that you want to roll a single
connection from the Roll From circuit to the Roll To circuit.
c. In the Roll From Circuit area, click the circuit that contains the Roll From connection.
Purpose This task reroutes a cross-connect on one circuit onto another circuit
resulting in a new destination.
Tools/Equipment None
Prerequisite Procedures DLP-F181 Log into CTC, page 16-34
“DLP-F253 Provision RS-DCC Terminations” task on page17-45 for the
ports involved in the roll
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher