18-65
Cisco ONS 15600 SDH Procedure Guide, R8.0
October 2007
Chapter18 DLPs F300 to F399
DLP- F353 Roll Two Cross-Connects on One Optical Circuit Using Automatic Routing
Step16 If you checked Review Route Before Creation in Step12:
a. In the Roll Route Review and Edit area, review the circuit route. To add or delete a circuit span,
select a node on the circuit route. Blue arrows show the circuit route. Green arrows indicate spans
that you can add. Click a span arrowhead, then click Include to include the span or Remove to
remove the span.
b. If the provisioned circuit does not reflect the routing and configuration you want, click Back to
verify and change circuit information.
Step17 Click Finish.
In the Circuits tab, verify that a new circuit appears. This circuit is the Roll To circuit. It is designated
with the Roll From circuit name appended with ROLL**.
Step18 Click the Rolls tab. Two new rolls now appear. For each pending roll, view the Roll Valid Signal status.
When one of the following requirements is met, continue with Step19.
If the Roll Valid Signal status is true, a valid signal was found on the new port.
If the Roll Valid Signal status is false, a valid signal was not found. Wait until the signal is found
before continuing with the next step. If a valid signal is not found, refer to the Cisco
ONS 15600 SDH Troubleshooting Guide. To cancel the roll, see the “DLP-F357 Cancel a Roll” task
on page 18-70.
The roll is a one-way destination roll and the Roll Valid signal status is false. It is not possible to
get a Roll Valid Signal status of true for a one-way destination roll.
Note If you have completed a roll, you cannot cancel the sibling roll. You must cancel the two
rolls together.
Note You cannot cancel an automatic roll after a valid signal is found.
A roll can be forced onto the Roll To Circuit destination without a valid signal by using the Force
Valid Signal button. If you choose Force Valid Signal, traffic on the circuit that is involved in the
roll will be dropped once the roll is completed.
Step19 If you selected Manual in Step 5, click both rolls on the Rolls tab and click Complete to route the traffic
to the new port. If you selected Auto, continue with Step20.
Note You cannot complete a roll if you cancelled the sibling roll. You must complete the two rolls
together.
Step20 For both manual and automatic rolls, click Finish to complete circuit roll process.
Step21 Return to your originating procedure (NTP).