Chapter 18 DLPs F300 to F399

DLP- F340 Change an MS-SPRing Node ID

East Line—Assign the east MS-SPRing port for the node from the drop-down list.

Step 5 Click OK.

Note Some or all of the following alarms will appear until all the MS-SPRing nodes are provisioned: E-W MISMATCH, RING MISMATCH, APSCIMP, APSDFLTK, and MSSP-OOSYNC. The alarms will clear after you configure all the nodes in the MS-SPRing.

Step 6 From the View menu, choose Go to Other Node.

Step 7 In the Select Node dialog box, choose the next node that you want to add to the MS-SPRing.

Step 8 Repeat Steps 1 through 7 at each node that you want to add to the MS-SPRing. When all nodes have been added, continue with Step 9.

Step 9 From the View menu, choose Go to Network View. After 10 to 15 seconds, verify the following:

A green span line appears between all BLSR nodes.

All E-W MISMATCH, RING MISMATCH, APSCIMP, APSDFLTK, and MSSP-OOSYNC alarms are cleared.

Step 10 Return to your originating procedure (NTP).

DLP-F340 Change an MS-SPRing Node ID

 

Purpose

This task changes an MS-SPRing node ID.

 

Tools/Equipment

None

 

Prerequisite Procedures

DLP-F181 Log into CTC, page 16-34

 

Required/As Needed

As needed

 

Onsite/Remote

Onsite or remote

 

Security Level

Provisioning or higher

 

 

Step 1

From the View menu, choose Go to Network View.

Step 2

On the network map, double-click the node with the node ID you want to change.

Step 3

From node view, click the Provisioning > MS-SPRingtabs.

Step 4

Choose a Node ID number. Do not choose a number already assigned to another node in the same

 

MS-SPRing.

 

Step 5

Click Apply.

 

Step 6

Return to your originating procedure (NTP).

 

 

 

 

 

Cisco ONS 15600 SDH Procedure Guide, R8.0

 

 

 

 

 

 

October 2007

 

 

18-41

 

 

 

 

 

Page 41
Image 41