NOTE: Duplex models only.

Number of Copies. Set the numbers of copies to be printed; the choices are 1,10, 50, 100, or 500.

1.Press the Home button.

2.Open the following menus:

Administration

Troubleshooting

Diagnostic Tests

3.Press the Down arrow to highlight PAPER PATH TEST, and then press the OK button.

4.Select the paper-path test options for the test you want to run.

Manual sensor test

Use this diagnostic test to manually test the product sensors and switches. Each sensor is represented by a letter and number on the control panel display.

1.Press the Home button .

2.Open the following menus:

Administration

Troubleshooting

Diagnostic Tests

3.Press the Down arrow to highlight the Manual Sensor Test item, and then press the OK button.

To exit this diagnostic, press the Stop button , and then select EXIT TROUBLESHOOTING.

Menus cannot be opened during this test, so the OK button serves the same function as the Stop button .

Table 3-20Manual sensor diagnostic tests

 

Sensor or switch name

Sensor or switch number

 

 

 

 

 

 

 

 

Front door opening/closing switch

PS14

 

 

 

 

 

 

 

 

Right door opening/closing sensor

PS15

 

 

 

 

 

 

 

 

A TOP (top of page) sensor

PS5

 

 

 

 

 

 

 

 

Fuser loop 1 sensor

PS7

 

 

 

 

 

 

 

 

Fuser loop 2 sensor

PS8

 

 

 

 

 

 

 

 

Fuser pressure-release sensor

PS9

 

 

 

 

 

 

 

 

Fuser output sensor

PS6

 

 

 

 

 

 

 

ENWW

Tools for troubleshooting

289

Page 313
Image 313