Developer alienation sensor (PS11)

This sensor is located inside the main-drive assembly and cannot be accessed for direct manual testing. Use the paper path sensor test to test this sensor.

1.Press the Home button .

2.Open the following menus:

Administration

Troubleshooting

Diagnostic Tests

3.Press the Down arrow to highlight the Paper Path Sensors item, and then press the OK button.

4.Press the Down arrow to highlight Start, and then check the control-panel display for sensor response (watch the developer alienation sensor (PS11) in the list).

5.If there is no response, replace the main drive assembly.

298 Chapter 3 Solve problems

ENWW

Page 322
Image 322
HP Enterprise CP5525 manual Developer alienation sensor PS11, Administration Troubleshooting Diagnostic Tests