X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow

1.Check the supplies status page to make sure the toner cartridges are not past their useful life.

2.Check the ITB for damage.

3.Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush.

4.If error persists, replace the registration sensor assembly.

54.0X.0B or 54.0X.0C

Density sensor out of range error or Dhalf calibration failure

X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow

1.Check the supplies status page to make sure the toner cartridges are not past their useful life.

2.Check the ITB for damage.

3.Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush.

4.If error persists, replace the registration sensor assembly.

54.0X.0D or 54.0X.0E

Optical memory element abnormal or CPR sensor out of range

X = 0 black, X = 1 cyan, X = 2 magenta, X = 3 yellow

1.Check the supplies status page to make sure the toner cartridges are not past their useful life.

2.Check the ITB for damage.

3.Make sure the CPR sensor is not contaminated with toner or paper dust. Clean the sensor with compressed air and soft brush.

4.If error persists, replace the registration sensor assembly.

55.00.YY DC controller error To continue, turn off then on

Description

DC controller PCA error

55.00.01 (event code) DC controller memory error

55.00.03 (event code

DC controller no engine response

55.00.04 (event code

DC controller communications timeout

ENWW