HP Enterprise CP5525 manual 59.0X.50 Error To continue, turn off then on, 59.00.F0

Models: Enterprise CP5525

1 686
Download 686 pages 10.87 Kb
Page 472
Image 472

Developer alienation motor (M6) error

1.Use the developer engagement and disengagement drive test in the component test to verify that the disengagement mechanism is properly functioning. If it is not, replace the ITB motor assembly.

2.Use the sensor test in the Manual sensor test to verify that the developer disengagement sensor (PS11) is properly functioning. If it is not, replace the main drive assembly.

3.If the product has been serviced, check the connector (J518) on the developer disengagement motor, the connector (J1005) on the driver PCA and the connector (J91) on the DC controller PCA.

59.00.F0

T1 alienation mechanism failure

1.Make sure that the ITB is correctly installed.

2.Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly.

3.Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly.

4.If the product has been serviced, check the connector (J181) on the DC controller PCA.

59.0X.50 Error To continue, turn off then on

Description

Motor startup error

X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow

Recommended action

59.05.50

Black image drum start up error (ITB motor; M1)

1.Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly.

2.If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.

59.06.50 or 59.07.50 or 59.08.50

CMY drum motor (M2) start up error

1.Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly.

2.If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.

448 Chapter 3 Solve problems

ENWW

Page 472
Image 472
HP Enterprise CP5525 manual 59.0X.50 Error To continue, turn off then on, 59.00.F0, Recommended action 59.05.50