Table 3-51Causes and solutions for fuser delivery stationary jams

Cause

Solution

 

 

The fuser roller or pressure roller is worn or

Replace the fuser. See Fuser on page 93.

deformed.

 

 

 

The fuser-delivery roller is deformed.

 

 

 

The gear of the fuser-delivery roller is

 

damaged.

 

 

 

Poor contact of the fuser-output sensor

Reconnect the connector J131 on the DC controller PCA.

connector.

 

 

 

The fuser-output sensor (PS6) is defective.

Run the manual sensor test to verify that the fuser-output sensor is functioning

 

properly. See Fuser output sensor (PS6) on page 297. If it is not, replace the

 

fuser. See Fuser on page 93.

 

 

Jams in the duplex area (duplex models only)

Table 3-52Causes and solutions for duplexing reverse jams

Cause

Solution

 

 

The duplex reverse roller is worn or deformed.

Replace the fuser. See Fuser on page 93.

 

 

The duplex feed roller is worn or deformed.

Replace the right door. See Right-door assembly on page 126.

Poor contact of the duplex reverse-motor (M7) Reconnect the connectors (J520) on the duplex reverse motor, intermediate

connector

connectors (J552L and J552D), connector (J1006) on the driver PCA, and

 

connectors (J93; J92; J91) on the DC controller PCA.

 

 

The duplex reverse motor is defective.

Replace the duplex drive assembly. See Duplex drive assembly (duplex

 

models) on page 187.

 

 

Table 3-53Causes and solutions for duplex repick jams

Cause

Solution

 

 

The duplex re-pickup sensor lever is set

Check the sensor lever to make sure it is set correctly. If it is damaged, replace

incorrectly or damaged.

the right door assembly. See Right-door assembly on page 126.

 

 

The spring of the duplex re-pickup sensor

Check the spring and place it in correct position.

lever is unhooked.

 

 

 

Poor contact of the duplex reverse solenoid

Reconnect the intermediate connectors (J522L and J522D), connector (J1005)

(SL3) connector

on the driver PCA, and connectors (J93; J92; J91) on the DC controller PCA.

 

 

The duplex reverse solenoid is defective.

Replace the duplex-drive assembly. See Duplex drive assembly (duplex

 

models) on page 187.

 

 

The duplex flapper is damaged or

Replace the delivery assembly. See Duplex drive assembly (duplex models)

malfunctioning.

on page 187.

 

 

The duplex reverse solenoid is defective.

Replace the duplex-drive assembly. See Duplex drive assembly (duplex

 

models) on page 187.

 

 

ENWW

Clear jams 509