Nortel Networks NN44200-700 System troubleshooting, Beep, Message, Description, count, Action

Models: NN44200-700

1 150
Download 150 pages 15.47 Kb
Page 31
Image 31
Manual background

 

 

1002rp server 31

 

 

 

Beep

Message

Description

count

 

 

 

 

 

7

Processor Exception

The CPU on the processor board generated an exception

 

Interrupt Error

interrupt.

8

Display Memory

The system video adapter is missing, or its memory is

 

Read/Write Error

faulty.

 

 

Note: This error is not fatal.

9

ROM Checksum Error

The ROM checksum value does not match the value

 

 

encoded in the BIOS.

 

 

 

System troubleshooting

Trouble symptom

Action

The system appears dead.

Check if the power cord is properly plugged in the power outlet.

 

 

If the system is a direct current (dc) version, the power cables

 

 

can be reversed; ensure that the polarity of the cables is correct.

The server does not

Ensure that the breaker corresponding to the cable is in the ON

boot.

 

position.

 

 

The server emits no

Ensure that the correct type of cable is used, depending on the

beeps.

 

type of power supply (ac or dc).

 

 

The fans do not turn.

Check if other equipment plugged in the same power outlet works.

Note: If the fans are turning, but the system emits no beeps, check if the monitor is turned on.

Check if the two LEDs on the power supplies (at the back of the server) are on or red.

If the LEDs are not on, check the power supply fuse.

If the LEDs are on and red, one or both power supplies is not plugged in or plugged in incorrectly, or the connection pins on the power supplies are bent or missing.

Nortel CallPilot

Troubleshooting Reference Guide

NN44200-700 01.05 Standard

5.026 June 2007

Copyright © 2007, Nortel Networks

Page 31
Image 31
Nortel Networks NN44200-700 manual System troubleshooting, Beep, Message, Description, count, Trouble symptom, Action