40Chapter 3 Hardware troubleshooting
TroubleAction
All DSP diagnostics fail at system startup.
All the DSPs and DS30 links are reported as "All busy", but the monitor shows that the resources are only partially busy (Option 11 Meridian 1 configurations only).
Ensure that the
Ensure that the PCI backplane does not have Intel PCI bridge chips.
Shut down the server and open the lid. Power up the server and check if the PCI LED on the
If the PCI LED comes on at system startup and then turns off, but the other four green LEDs are still off after the system booted to the operating system, check the HAL and ensure that all its components are working properly. If the HAL components are working properly, one or more MPC8 cards can be defective. Replace the defective MPC8 cards.
If your system has two
If only one
The switch and the CallPilot system do not have the same ground connection. Ensure that both systems are plugged into the same power outlet and connected to a
The system starts up but attempts to boot to the operating system from the network.
The RAID packs are either not configured or degraded. The RAID system is not operational. Proceed as follows:
•Power down the system, plug the RAID card into the next set of four PCI slots and then turn on the system. If the system boots correctly to the operating system, then the PCI backplane is defective and you must replace it.
•Power down the system, open the server lid and turn on the system. If more than four lights remain on, the RAID controller is faulty. Power down the system, reseat the controller card, and turn on the system. If this action does not remedy the trouble, then the RAID controller card is defective and you must replace it.
Nortel CallPilot
Troubleshooting Reference Guide
5.026 June 2007