| 201i server 15 |
SCSI peripheral troubleshooting | |
|
|
Trouble | Action |
| |
The system does not start Note: The 201i server does not support this feature at this time. | |
from the |
|
The system displays | Ensure that the most recent version of the |
error messages while | installed on your system. |
the operating system is
installed from the
Newer
The
Because the SCSI cable can be plugged and unplugged from the faceplate of the 201i server, the cable connector pins can get bent or pushed in.
Inspect the connector of the SCSI cable and ensure that all the connector pins are straight and level. Ensure that the cable is properly and fully plugged in and latched to the 201i server faceplate.
When installing a new
Ethernet cable troubleshooting
TroubleAction
The Ethernet link LEDs are not on.
When an Ethernet cable is properly connected at both ends, the link LED associated with the Ethernet connector must be on at both ends of the Ethernet cable even when the operating system is not running.
The 201i faceplate has a row of four green LEDs labelled E, C, I, and S.
•The leftmost LED (E) is associated with the ELAN link.
•The second LED (C) is associated with the CLAN link.
Nortel CallPilot
Troubleshooting Reference Guide
5.026 June 2007