During startup, a message indicates that the System Event Log is full and the log must be cleared.
1005r server 47
8. Boot into service.
This is an unusual situation and appears only if the server was booted many times. View the log before clearing it. See the 1005r Hardware Maintenance and Diagnostics guide
After startup, the Intel Server Manager reports that one of the processors is disabled. This causes the system processes to slow down.
1.Power down the server.
2.Disconnect the power cord and wait 2 minutes.
3.Connect the power cord.
4.Power up the server.
SCSI and tape drive troubleshooting
Trouble | Action |
The SLR external tape drive was hot plugged | Select a device within the Windows device |
but does not appear in the device manager. | manager and then select Action > Rescan. The |
| drive should be detected. If not, ensure the |
| correct driver is installed. |
| If this does not resolve the problem, ensure the |
| external drive is powered up and not faulty. |
| Observe the LED codes on the tape drive for |
| errors pertaining to the tape drive only. |
The tape drive is plugged in correctly, but the | The tape drive may have been plugged into |
system experiences errors. (The drive cannot | the RAID external SCSI adaptor instead of |
be | the SCSI adaptor. Plug the tape into the |
| correct connector at the back of the server. For |
| instructions, see the 1005r Server Hardware |
| Installation Guide |
|
|
RAID troubleshooting
Trouble | Action |
The system boots but does not detect the RAID | Ensure the PCI raiser assembly is plugged in |
card. | correctly, aligned, and firmly pressed into the |
| slot. You must complete the reseating with the |
| server out of the rack and on a solid surface. |
The system boots and detects the RAID card but does not boot into Windows.
Check if any, or all, of the drives are offline.
Nortel CallPilot
Troubleshooting Reference Guide
5.026 June 2007