13

Chapter 3

Hardware troubleshooting

In this chapter

"201i server" (page 13) "703t server" (page 17) "1002rp server" (page 28) "1005r server" (page 41) "600r" (page 50)

201i server

System troubleshooting

Trouble

Action

The system emits beep

The state of the PC chip set is associated with beep codes. Some

codes.

codes indicate relatively harmless failure situations that allow you

 

to start up the CallPilot server, even though the system is not fully

 

functional unless you solve the trouble.

 

Some beep codes indicate catastrophic failures that cannot be

 

easily resolved at the customer site. For example, the series of

 

beep codes 1-3-3-1 indicates a defective or missing memory DIMM.

 

Declare the system an out-of-box failure (OBF) and return it to the

 

channel partner.

 

Note: The 201i server emits one pulse beep at startup. This is a

 

normal beep and does not indicate a system failure.

Nortel CallPilot

Troubleshooting Reference Guide

NN44200-700 01.05 Standard

5.026 June 2007

Copyright © 2007, Nortel Networks