9. PRINTINGS

9.1 Printing Types and the Details

Printing comprises trace printing and digital printing. The fixed-time printing and trace printing are executed even if any operation is not programmed.

1

Printing Types and the Details

Printing type

Trace printing (Cartridge pen)

 

Fixed-time

 

printing

 

Periodic

 

data printing

 

Digital data

 

printing

 

List 1

 

printing

 

List 2

pen)

printing

List 3

 

(Plotter

printing

Message

Printing

printing

Alarm

Data

printing

sync. mark

Digital

 

Time axis

 

printing

 

Power-on

 

printing

 

Operation

 

printing line

 

and

 

Operation

 

printing No.

 

Printer

 

check

 

printing

 

 

Printing details

 

 

Remarks

Trend printing is executed for each pen (channel)

 

 

 

 

 

 

 

 

 

 

 

1st pen

2nd pen

3rd pen

4th pen

 

 

Red

Green

Blue

Brown

 

 

 

 

 

 

 

 

 

The following details are printed on the fixed time.

 

 

10-1

(1) Year/Month/Day (2) Time (3) Time line (4) Chart speed (5) Scale, Engineering unit, Tag

 

Measured values are printed on the trace printing with programmed intervals. The

11-7

printing starts from the programmed start time line. The printing mode is different

depending on chart speed.

 

 

 

 

Measured values are printed on the trace printing. The printing mode is different

9-2

depending on chart speed.

 

 

 

 

 

 

 

Major parameters (Range/Printing range, Scale, Subtract printing, Periodic data

9-3

printing) are printed as a table.

 

 

 

 

 

 

 

The parameters (such as time axis synchronizing, message, items relating to

9-3

options) other than those involved in List 1 are printed as a table.

 

All parameters (List 1 + List 2) are printed as a table.

9-3

Message is printed

on the right

side of the

chart paper by selecting the

9-4

programmed message No.

 

 

 

 

 

 

 

Alarm details (time, alarm points, alarm type) are printed on the right side of the

10-4

chart paper when an alarm activates or an alarm is reset.

 

(1) When the time axis synchronization (POC) is switched on or off, its time, mark

9-6

(*), and ON or OFF are printed on the right side of the chart paper.

(2) When it is ON, a mark (*) is printed to the right of the time print of fixed-time

10-1

printing.

 

 

 

 

 

Year/Month/Day and time are printed on the left side of the chart paper when the

6-1

power is turned on.

 

 

 

 

 

 

 

 

 

For the remote contacts (option), it is required to program the "Operation printing

 

position" and select one of Act 1 to 4 in the "Remote contacts" programming.

 

(1) Printing line: When a contact signal (on) is applied to the allocated terminal,

13-4

the line is printed by 5 mm to the right of the programmed printing line

position.

 

 

 

 

 

(2)Operation printing No.: Operation printing No. (A to D) is printed at constant intervals to the left of the programmed printing line position.

When hardware check is executed by selecting the printer (plotter pen)

19-2

characters are printed for checking purpose.

 