-130-

22. SPECIFICATIONS

10 Option

1) Alarm outputs

Output types: cAlarm point output d FAIL output e Chart
paper end (C.End) output
Numbers of outputs: RD200 … 6 points
RD2800 …6 or 12 points
Contact capacity (with resistive load):
cMOS relay output … 240 V (AC, DC), 50 mA (AC, DC)
d Mechanical relay (Common for “a” and “c” contacts) …
100VAC 0.5 A, 240VAC 0. 2A, 100VDC 0.3 A
Output wiring: AND/OR output selection is available for each
alarm points (including FAIL and C.End)
Relay coil phase: Energize/Not energize selectable*
Relay output latch: Hold/Not hold selectable*
Alarm display latch: Hold/Not hold selectable*
*Common to all relays
Dimension: The following length will be added for the depth.
RD200…14 mm (MOS relay, Mechanical “c”
contact)
25 mm (Mechanical “a” contact)
RD2800…16 mm (MOS relay, Mechanical “c”
contact)
27 mm (Mechanical “a” contact)

2) Remote contacts

Input terminals: 4 points (Common terminals: 2 points)
Input signal: Contact (Open/Shorted)
Voltage when the contact is open: Approx. 5 V
Current when the contact is shorted: Approx. 2 mA
Operations: Up to 4 input terminals can be selectable in the
following table.
Operation Terminal
c Printing ON/OFF, 3 chart speeds 2
d Message (No.1 to No.5) printing 4
e Message (No. 1 and No. 2) printing 2
f Digital data printing 1
g List 1 printing 1
h List 2 printing 1
i List 3 printing 1
j Operation record A 1
k Operation record B 1
l Operation record C 1
Operation record D 1
Reset of totalization* 1
*This operation is only available for the “totalization” (option).

3) Printing format

Trace printing format, c Automatic range shift, d
Compressed/Expanded or e Zone scale, is selectable for
each channel.. The format e is common to all channels.
Automatic
range-shift
Printing area can be divided up to 5 ranges. It
switches the range according to the measured
values automatically for printing.
Compressed/
Expanded Specific printing range is compressed or
expanded for printing.
Zone scale Printing area is divided into 2 to 4 zones*. Data
of each channel is printed in the relevant zone.
*RD200 … 2, RD2800 … 2 to 4

4) Others

Options Detail
Communications
interface* Specify one of the following modes.
RS-232C, RS-422A, RS-485
Input resistance
for current input*
Capable up to ±50mA DC by connecting an
input resistance to the measuring input
terminal.
100: Applicable current ±50mA
250: Applicable current ±20mA
Math
expression*
One of following math expressions is
selectable for each channel.
Addition, subtraction, multiplication, division,
natural logarithm, logarithm, exponential,
square root, temperature/humidity, maximum,
minimum, average value, absolute value,
data communications input*, flow rate
compensation.
*This function is only available for the
“communications interface” (option).
Tota liz ing *
Totalizing measured values and calculation
results. Reset function is executed with
programmed intervals or remote contacts
signals*.
*This function is only available for the
“remote contacts” (option).
Transmitter
power supply* Power supply unit for the transmitter
generating input signal to the recorder
16 m chart paper RD200 only …. Total chart paper length of
15.6 m
* Exclusive instruction manual is provided.
11