8.BASIC PROGRAMMING

8.2 Range/Printing Range

4

Range No. Tables

1) Voltage input

Input type

Measuring range

Remarks

01-13.80 to 13.80 mV

02DC -27.60 to 27.60 mV

-69.00 to 69.0003mV

 

(mV)

 

 

 

 

 

04

-200.0

to

200.0

mV

For current

 

05

 

-500.0

to

500.0

mV

 

input, see

06

 

-2.000

to

2.000

V

 

Item 16.2.

07

DC

-5.000

to

5.000

V

 

08

-10.00

to

10.00

V

 

(V)

 

09

-20.00

to

20.00

V

 

 

 

10

 

-50.00

to

50.00

V

 

2) Thermocouple input (*1)

No.

Input

 

 

Measuring range

 

 

type

 

°

 

°

 

 

 

 

 

C

 

 

F

 

21

K

-200.0

to

300.0

-320.0

 

to

570.0

22

-200.0

to

600.0

-320

 

to

1110

23

 

-200

to

1370

-320

 

to

2490

24

E

-200.0

to

200.0

-320.0

 

to

390.0

25

-200.0

to

350.0

-320.0

 

to

660.0

26

 

-200

to

900

-320

 

to

1650

27

J

-200.0

to

250.0

-320.0

 

to

480.0

28

-200.0

to

500.0

-320.0

 

to

930.0

29

 

-200

to

1200

-320

 

to

2190

30

T

-200.0

to

250.0

-320.0

 

to

480.0

31

-200.0

to

400.0

-320.0

 

to

750.0

 

 

32

R

0

to

1200

32

 

to

2190

33

0

to

1760

32

 

to

3200

 

 

34

S

0

to

1300

32

 

to

2370

35

0

to

1760

32

 

to

3200

 

 

36

B

0

to

1820

32

 

to

3300

37

N

-200.0

to

400.0

-320.0

 

to

750.0

38

-200.0

to

750.0

-320

 

to

1380

39

 

-200

to

1300

-320

 

to

2370

No.

Input type

 

 

Measuring range

 

 

 

°C

 

°F

 

 

 

 

 

 

40

W-WRe26

0

to

2315

32

to 4200

41

WRe5-WRe26

0

to

2315

32

to 4200

43

PtRh40-

0

to

1888

32

to

3400

PtRh20

 

 

 

 

 

 

 

 

44

NiMo-Ni

-50.0

to

290.0

32.0

to

550.0

45

-50.0

to

600.0

32

to

1110

46

 

50

to

1310

32

to

2350

47

CR-AuFe

0.0

to

 

280.0K

0.0

to

300.0K

48

Platinel

0.0

to

350.0

-140.0

to

660.0

49

0.0

to

650.0

-140

to

1200

50

0

to

1390

-140

to

2530

 

51

U

-200.0

to

250.0

-320.0

to

480.0

52

-200.0

to

500.0

-320.0

to

930.0

53

 

-200.0

to

600.0

-320

to

1110

54

L

-200.0

to

250.0

-320.0

to

480.0

55

-200.0

to

500.0

-320.0

to

930.0

56

 

-200

to

900

-320

to

1650

3) Resistance thermometer input (*2)

No.

Input

 

 

Measuring range

 

 

type

 

°

 

°

 

 

 

 

 

C

 

F

 

70

Pt100

-140.0

to

150.0

-220.0

to

300.0

71

-200.0

to

300.0

-320.0

to

550.0

(JIS’97)

72

-200.0

to

850.0

-320

to

1560

 

73

Pt100

-140.0

to

150.0

-220.0

to

300.0

74

QPt100

-200.0

to

300.0

-320.0

to

550.0

75

JIS’89

-200.0

to

649.0

-320

to

1200

76

JPt100

-140.0

to

150.0

-220.0

to

300.0

77

-200.0

to

300.0

-320.0

to

550.0

78

 

-200.0

to

649.0

-320

to

1200

79

Pt50

-200.0

to

649.0

-320

to

1200

80

Pt-Co

4.0

to

374.0K

4.0

to 374.0K

*1: (1) No.21 to 39: IEC584, JIS C 1602-1995

*2: (1) No.70 to 72: IEC751(1995), JIS C 1604-1997

(2) No.73 to 75: IEC751(1983), JIS C 1604-1989

(2) No.40 to 50: ASTM

JIS C 1606-1989

(3) No.51 to 56: DIN43710

(3) No.76 to 78: JIS C 1604-1981

 

 

JIS C 1606-1989

 

(4) No.79: JIS C 1604-1981

Remarks Decimal point position and engineering units

Decimal point position: Even if the decimal point position is programmed in the printing range, the actual display/printing position is shown as described in the table above depending on the range No. For changing the decimal point position, see Section 11.2 “Scale programming”.

Engineering units: Engineering unit is shown as described in the table above depending on range No. (Temperature unit is fixed to “°C” except No. 47 and 80). For changing the engineering unit, see Section 11.8 “Unit programming”.

-42-