WARNINGS
This paragraph covers important warnings for safety to be observed before reading the instructions. A full understanding of the following warnings is required. These warnings are important for the prevention of danger to human bodies as well as accidents with your recorder.
1. Switch and overcurrent protective device
Your recorder is not provided with a power switch or a replaceable overcurrent protective device. Prepare a switch and an overcurrent protective device (circuit breakers, circuit protectors or similar units) for the power supply within 3 m of your recorder in a location where you can reach easily.
Use a switch and an overcurrent protective device conforming to
2. Be sure to ground your recorder
Before turning on the power, connect the protective conductor terminal your recorder to the protective conductor of the power supply facility. Do not disconnect this wiring in running of your recorder to prevent an electric shock.
3. Before turning on the power supply
In order to ensure safety, before turning on the external power switch, make sure that the power voltage is within the range indicated on the power supply label.
4. Don’t repair or modify your recorder.
Make sure that a service engineer approved by the CHINO CORPORATION is ONLY permitted to repair or modify your recorder by replacing parts. Otherwise, it may be damaged or will not function correctly, or an accident such as an electric shock may result. For usual operation, it is not necessary to pull out an internal unit from a case.
L | N | Power/protective |
|
| |
|
| conductor |
Overcurrent |
| terminals |
| To the protective | |
protective |
| |
| conductor of power | |
device |
| |
| supply facility | |
(250V 3A) |
| |
| Power supply | |
|
| |
|
| Switch |
Reference Fuse in power supply unit
The following fuse is mounted in the power supply unit of your recorder for safety use. However, this fuse is not replaceable.
| Manufacturer | Model | Ratings |
|
| SCHURTER | SPT001.2508 | 250VAC |
|
| LITTEL FUSE | 21502.5 |
| |
| 2.5A |
| ||
| WICKMANN | 19181 |
| |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
Power supply label
50/60Hz 60VA MAX
Note: This figure is for RD200 series.
5. Use your recorder in accordance with this instruction manual.
Use your recorder correctly and safely in accordance with this instruction manual. CHINO CORPORATION will not be responsible for any injury, damage, lost profit or any other claim, which may result from its wrong use.
6.Turn off the power supply if an abnormal symptom occurs.
If any abnormal odor, noise or any smoke occurs, or if your recorder becomes too hot to be touched, turn off the power supply immediately and contact your local CHINO sales agent.
-5-