-129-

22. SPECIFICATIONS

9 Accuracy Ratings
No.
Input type Measuring range Reference
range Accuracy
rating
01 -13.80 to 13.80mV ±13.8mV
02 -27.60 to 27.60mV ±27.6mV
03 -69.00 to 69.00mV ±69.0mV
04 -200.0 to 200.0mV ±200.0mV
05
DC
(mV)
-500.0 to 500.0mV ±500.0mV
06 -2.000 to 2.000V ±2V
07 -5.000 to 5.000V ±5V
08 -10.00 to 10.00V ±10V
09 -20.00 to 20.00V ±20V
10
DC
(V)
-50.00 to 50.00V ±50V
±0.1% ± 1 d
21 -200.0 to 300.0°C ±13.8mV
22 -200.0 to 600.0°C ±27.6mV
23 K -200.0 to 1370 °C ±69.0mV
24 -200.0 to 200.0°C ±13.8mV
25 -200.0 to 350.0°C ±27.6mV
26 E -200 to 900°C ±69.0mV
27 -200.0 to 250.0°C ±13.8mV
28 -200.0 to 500.0°C ±27.6mV
29 J -200 to 1200°C ±69.0mV
30 -200.0 to 250.0°C ±13.8mV
31 T -200.0 to 400.0°C ±27.6mV
32 0 to 1200 °C ±13.8mV
33 R 0 to 1760 °C ±27.6mV
34 0 to 1300 °C ±13.8mV
35 S 0 to 1760 °C ±27.6mV
36 B 0 to 18 20 °C ±13.8mV
±0.1% ± 1 d
37 -200.0 to 400.0°C ±13.8mV
38 -200.0 to 750.0°C ±27.6mV
39 N -200 to 1300 °C ±69.0mV
40 WWRe26 0 to 2315°C ±69.0mV
±0.15% ± 1 d
41 WRe5
WRe26 0 to 2315°C ±69.0mV
43 PtRh40-
PtRh20 0 to 1888°C ±13.8mV
44 -50.0 to 290.0°C ±13.8mV
45 -50.0 to 600.0°C ±27.6mV
46 NiMo-Ni -50 to 1310 °C ±69.0mV
47 CR-AuFe 0.0 to 280.0K ±13.8mV
±0.2% ± 1 d
48 0.0 to 350.0°C
±13.8mV
49 0.0 to 650.0°C
±27.6mV
50 Platinel ll 0 to 1395°C ±69.0mV
51 -200.0 to 250.0°C ±13.8mV
52 -200.0 to 500.0°C ±27.6mV
53 U -200.0 to 600.0°C ±69.0mV
±0.15% ± 1 d
54 -200.0 to 250.0°C ±13.8mV
55 -200.0 to 500.0°C ±27.6mV
56 L -200 to 900°C ±69.0mV
±0.1% ± 1 d
70 -140.0 to150.0°C 160 ±0.15% ± 1 d
71 -200.0 to 300.0°C 220
72
Pt100
(JIS’97) -200 .0 to 850.0°C 400 ±0.1% ± 1 d
73 -140.0 to 150.0°C 160 ±0.15% ± 1 d
74 -200.0 to 300.0°C 220
75
Pt100
QPt100
JIS’89 -200.0 to 649.0°C 400 ±0.1% ± 1 d
76 -140.0 to 150.0°C 160 ±0.15% ± 1 d
77 -200.0 to 300.0°C 220
78 JPt100 -200.0 to 649.0°C 400 ±0.1% ± 1 d

No.
Input type Measuring range Reference
range Accuracy
rating
79 Pt50 -200.0 to 649.0°C 220 ±0.1% ± 1 d
80 Pt-Co 4.0 to 374.0K 220 ±0.15% ± 1 d
Note) “± 1 d” at accuracy rating stands for ± 1 digit.
Note) Thermocouple inputs do not include reference junctio n
compensation accuracy.
The Indication equivalent to 200 µV may vary under the
test environment of EMC directive.

Exceptions to accuracy rating
Input type Measuring range Accuracy rating
K, E, J, T, L -200 to 0°C
R, S 0 to 400°C ±0.2% ± 1 digit
0 to 400°C Not specified
B 400 to 800°C ±0.15% ± 1 digit
N, U -200 to 0°C ±0.3% ± 1 digit
0 to 100°C ±4% ± 1 digit
W-WRe26 100 to 300°C ±0.5 % ± 1 digit
0 to 300°C ±1.5% ± 1 digit
PtRh40-PtRh20 300 to 800°C ±0.8% ± 1 digit
0 to 20K ±0.5% ± 1 digit
CR-AuFe 20 to 50K ±0.3% ± 1 digit
Pt100 (’97) 700 to 850°C ±0.15% ± 1 digit
Pt-Co 4 to 50K ±0.3% ± 1 digit
Note) Thermocouple input is converted into the reference
range.